You are here

USER-CENTERED VIRTUAL ENVIRONMENT ASSESSMENT AND DESIGN FOR COGNITIVE REHABILITATION APPLICATIONS

Download pdf | Full Screen View

Date Issued:
2006
Abstract/Description:
Virtual environment (VE) design for cognitive rehabilitation necessitates a new methodology to ensure the validity of the resulting rehabilitation assessment. We propose that benchmarking the VE system technology utilizing a user-centered approach should precede the VE construction. Further, user performance baselines should be measured throughout testing as a control for adaptive effects that may confound the metrics chosen to evaluate the rehabilitation treatment. To support these claims we present data obtained from two modules of a user-centered head-mounted display (HMD) assessment battery, specifically resolution visual acuity and stereoacuity. Resolution visual acuity and stereoacuity assessments provide information about the image quality achieved by an HMD based upon its unique system parameters. When applying a user-centered approach, we were able to quantify limitations in the VE system components (e.g., low microdisplay resolution) and separately point to user characteristics (e.g., changes in dark focus) that may introduce error in the evaluation of VE based rehabilitation protocols. Based on these results, we provide guidelines for calibrating and benchmarking HMDs. In addition, we discuss potential extensions of the assessment to address higher level usability issues. We intend to test the proposed framework within the Human Experience Modeler (HEM), a testbed created at the University of Central Florida to evaluate technologies that may enhance cognitive rehabilitation effectiveness. Preliminary results of a feasibility pilot study conducted with a memory impaired participant showed that the HEM provides the control and repeatability needed to conduct such technology comparisons. Further, the HEM affords the opportunity to integrate new brain imaging technologies (i.e., functional Near Infrared Imaging) to evaluate brain plasticity associated with VE based cognitive rehabilitation.
Title: USER-CENTERED VIRTUAL ENVIRONMENT ASSESSMENT AND DESIGN FOR COGNITIVE REHABILITATION APPLICATIONS.
55 views
36 downloads
Name(s): Fidopiastis, Cali, Author
Rolland, Jannick , Committee Chair
University of Central Florida, Degree Grantor
Type of Resource: text
Date Issued: 2006
Publisher: University of Central Florida
Language(s): English
Abstract/Description: Virtual environment (VE) design for cognitive rehabilitation necessitates a new methodology to ensure the validity of the resulting rehabilitation assessment. We propose that benchmarking the VE system technology utilizing a user-centered approach should precede the VE construction. Further, user performance baselines should be measured throughout testing as a control for adaptive effects that may confound the metrics chosen to evaluate the rehabilitation treatment. To support these claims we present data obtained from two modules of a user-centered head-mounted display (HMD) assessment battery, specifically resolution visual acuity and stereoacuity. Resolution visual acuity and stereoacuity assessments provide information about the image quality achieved by an HMD based upon its unique system parameters. When applying a user-centered approach, we were able to quantify limitations in the VE system components (e.g., low microdisplay resolution) and separately point to user characteristics (e.g., changes in dark focus) that may introduce error in the evaluation of VE based rehabilitation protocols. Based on these results, we provide guidelines for calibrating and benchmarking HMDs. In addition, we discuss potential extensions of the assessment to address higher level usability issues. We intend to test the proposed framework within the Human Experience Modeler (HEM), a testbed created at the University of Central Florida to evaluate technologies that may enhance cognitive rehabilitation effectiveness. Preliminary results of a feasibility pilot study conducted with a memory impaired participant showed that the HEM provides the control and repeatability needed to conduct such technology comparisons. Further, the HEM affords the opportunity to integrate new brain imaging technologies (i.e., functional Near Infrared Imaging) to evaluate brain plasticity associated with VE based cognitive rehabilitation.
Identifier: CFE0001203 (IID), ucf:46946 (fedora)
Note(s): 2006-08-01
Ph.D.
Engineering and Computer Science, Other
Doctorate
This record was generated from author submitted information.
Subject(s): virtaul reality
head-mounted displays
visual perception
cognitive rehabilitation
Persistent Link to This Record: http://purl.flvc.org/ucf/fd/CFE0001203
Restrictions on Access: public
Host Institution: UCF

In Collections