Abstract/Description:
Mercury (Hg) is a well-known hazardous environmental contaminant existing in several forms, but all are toxic to human in one way or the others. Since Hg usually settles into water polluting the environment and accumulating in living organisms, it is crucial to monitor Hg levels in the aquatic ecosystem. Although there are many well established techniques currently used to detect Hg, most of them require elaborate and time-consuming sample preparation and pre-concentration procedures, as well as costly and bulky equipment that limit their practical application in the field. In order to overcome the existent limitations in Hg determination methods, Hernandez and co-workers proposed the first surface Plasmon resonance (SPR) (-) based Hg sensor using gold nanorods (AuNRs) that offers high sensitivity and selectivity, attributed to the strong affinity between Au and Hg. In this dissertation, I first present my contribution to the understanding of the effect of size and aspect ratio of AuNRs on the limit of detection (LOD) and the dynamic range (DR) of the SPR-based Hg sensor using the qualitative model. In this part I demonstrate how both sensitivity and DR can be improved simultaneously via a modified wet chemistry procedure. Then, I show our approach towards the immobilization of AuNRs silane coated glass slides to expand the application of the SPR-based Hg sensor to stream-flow. Finally, I present the design and fabrication of the first real prototype of the SPR-based Hg sensor, and its application in stream-flow detection and speciation of mercury in the environment. The outcomes of my research have resulted in an innovative real-time portable Hg sensor apparatus with the desired high sensitivity, selectivity and DR to be used in stream-flow applications in Oak Ridge National Labs sites.
Title: Development of a nano-sensing approach and a portable prototype for real-time detection and quantification of free mercury in stream-flow: combining science and engineering in pro of the environment.
37 views
17 downloads
Name(s): Chemnasiri, Warinya, Author
Hernandez, Florencio, Committee Chair
Kuebler, Stephen, Committee Member
Zou, Shengli, Committee Member
Uribe Romo, Fernando, Committee Member
Huo, Qun, Committee Member
University of Central Florida, Degree Grantor
Type of Resource: text
Date Issued: 2015
Publisher: University of Central Florida
Language(s): English
Abstract/Description: Mercury (Hg) is a well-known hazardous environmental contaminant existing in several forms, but all are toxic to human in one way or the others. Since Hg usually settles into water polluting the environment and accumulating in living organisms, it is crucial to monitor Hg levels in the aquatic ecosystem. Although there are many well established techniques currently used to detect Hg, most of them require elaborate and time-consuming sample preparation and pre-concentration procedures, as well as costly and bulky equipment that limit their practical application in the field. In order to overcome the existent limitations in Hg determination methods, Hernandez and co-workers proposed the first surface Plasmon resonance (SPR) (-) based Hg sensor using gold nanorods (AuNRs) that offers high sensitivity and selectivity, attributed to the strong affinity between Au and Hg. In this dissertation, I first present my contribution to the understanding of the effect of size and aspect ratio of AuNRs on the limit of detection (LOD) and the dynamic range (DR) of the SPR-based Hg sensor using the qualitative model. In this part I demonstrate how both sensitivity and DR can be improved simultaneously via a modified wet chemistry procedure. Then, I show our approach towards the immobilization of AuNRs silane coated glass slides to expand the application of the SPR-based Hg sensor to stream-flow. Finally, I present the design and fabrication of the first real prototype of the SPR-based Hg sensor, and its application in stream-flow detection and speciation of mercury in the environment. The outcomes of my research have resulted in an innovative real-time portable Hg sensor apparatus with the desired high sensitivity, selectivity and DR to be used in stream-flow applications in Oak Ridge National Labs sites.
Identifier: CFE0006283 (IID), ucf:51589 (fedora)
Note(s): 2015-12-01
Ph.D.
Sciences, Chemistry
Doctoral
This record was generated from author submitted information.
Subject(s): Nanotechnology -- Nanoparticles -- Gold nanorods -- Mercury Sensor -- Localized surface Plasmon resonance -- Plasmonics -- Sensor prototype -- Nano-sensing -- Portable sensor -- Real-time detection -- Quantification of free mercury
Persistent Link to This Record: http://purl.flvc.org/ucf/fd/CFE0006283
Restrictions on Access: campus 2021-06-15
Host Institution: UCF

In Collections