Current Search: cooling (x)
Pages
-
-
Title
-
Coupled Usage of Discrete Hole and Transpired Film For Better Cooling Performance.
-
Creator
-
Torrance, Michael, Kapat, Jayanta, Vasu Sumathi, Subith, Xu, Chengying, University of Central Florida
-
Abstract / Description
-
Electricity has become so ingrained in everyday life that the current generation has no knowledge of life without it. The majority of power generation in the United States is the result of turbines of some form. With such widespread utilization of these complex rotating machines, any increase in efficiency translates into improvements in the current cost of energy. These improvements manifest themselves as reductions in greenhouse emissions or possible savings to the consumer. The most...
Show moreElectricity has become so ingrained in everyday life that the current generation has no knowledge of life without it. The majority of power generation in the United States is the result of turbines of some form. With such widespread utilization of these complex rotating machines, any increase in efficiency translates into improvements in the current cost of energy. These improvements manifest themselves as reductions in greenhouse emissions or possible savings to the consumer. The most important temperature regarding turbine performance is the temperature of the hot gas entering the turbine, denoted turbine inlet temperature. Increasing the turbine inlet temperature allows for increases in power production as well as increases in efficiency. The challenge with increasing this temperature, currently the hottest temperature seen by the turbine, is that it currently already exceeds the melting point of the metals that the turbine is manufactured from. Active cooling of stationary and rotating components in the turbine is required. Cooling flows are taken from bleed flows from various stages of the compressor as well as flow from the combustor shell. This cooling flow is considered wasted air as far as performance is concerned and can account for as much as 20% of the mass flow in the hot gas path. Lowering the amount of air used for cooling allows for more to be used for performance gain.Various technologies exist to allow for greater turbine inlet temperatures such as various internal channel features inside of turbine blades, film holes on the surface to cool the outside of the airfoil as well as thermal barrier coatings that insulate the airfoils from the hot mainstream flow. The current work is a study of the potential performance impact of coupling two effusion technologies, transpiration and discrete hole film cooling. Film cooling and transpiring flows are individually validated against literature before the two technologies are coupled. The coupled geometries feature 13 film holes of 7.5mm diameter and a transpiring strip 5mm long in the streamwise direction. The first coupled geometry features the porous section upstream of the film holes and the second features it downstream. Both geometries use the same crushed aluminum porous insert of nominal porosity of 50%. Temperature sensitive paint along with an 'adiabatic' Rohacell surface (thermal conductivity of 0.029W/m-K) are used to measure adiabatic film cooling effectiveness using a scientific grade high resolution CCD camera. The result is local effectiveness data up to 50 film hole diameters downstream of injection location. Data is laterally averaged and compared with the baseline cases. Local effectiveness contours are used to draw conclusions regarding the interactions between transpiration and discrete hole film cooling. It is found that a linear superposition method is only valid far downstream from the injection location. Both coupled geometries perform better than transpiration or the discrete holes far downstream of the injection location. The coupled geometry featuring the transpiring section downstream of the film holes matches the transpiration effectiveness just downstream of injection and surpasses both transpiration and film cooling further downstream.
Show less
-
Date Issued
-
2012
-
Identifier
-
CFE0004799, ucf:49721
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0004799
-
-
Title
-
INVESTIGATION ON INTERACTIONS OF UNSTEADY WAKES AND FILM COOLING ON AN ANNULAR ENDWALL.
-
Creator
-
Golsen, Matthew, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
In recent decades, greater interest in the effect of rotational wakes on gas turbine film cooling applications has produced increasing numbers of studies on these unsteady phenomena. Wakes are primarily shed from upstream components such as transition duct walls, stator vanes, and rotors. Studies have shown that in areas of unsteady flow, the best performing parameters in conventional steady investigations may not be the best for unsteady applications. One common method of modeling the...
Show moreIn recent decades, greater interest in the effect of rotational wakes on gas turbine film cooling applications has produced increasing numbers of studies on these unsteady phenomena. Wakes are primarily shed from upstream components such as transition duct walls, stator vanes, and rotors. Studies have shown that in areas of unsteady flow, the best performing parameters in conventional steady investigations may not be the best for unsteady applications. One common method of modeling the unsteady wake interaction in subsonic flows is the use of spoke wheel type wake generators using cylindrical rods to produce the velocity detriment and local increase in turbulence intensity. Though the impact of wakes have been studied for decades on airfoil losses and boundary layer transition, only recently has the film cooling and wake interaction been investigated. The existing work is primarily on leading edge models and airfoil cascades. The primary parameter characterizing the unsteady wakes is the dimensionless or reduced frequency known as the Strouhal number. The film cooling jet itself has dominant frequencies resulting from the shear and the jet trailing wake shedding, depending on the injectant flow rate. There exist great deficiencies in the fundamental understanding of the interaction of these two frequencies. Heat transfer considerations are also relatively recent being studied only since the early 1990's. Heat transfer coefficients and film cooling effectiveness have been reported for leading edge and linear airfoil cascades. In the case of the linear cascade, no data can be taken near the endwall region due to the varying tangential velocity of wake generating rod. The current work expands on this initiative incorporating a sector annular duct as the test setting for the rotating wakes focusing on this endwall region. Studies in to the effect of the rods in this alternate orientation include film cooling effectiveness using temperature sensitive paint, impact of wake rod to film cooling hole diameter ratio, and time accurate numerical predictions and comparisons with experimental work. Data are shown for a range of momentum flux ratios and Strouhal numbers. The result of this work sets the stage for the complete understanding of the unsteady wake and inclined jet interaction.
Show less
-
Date Issued
-
2011
-
Identifier
-
CFH0004094, ucf:44796
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFH0004094
-
-
Title
-
Simulation of Heat/Mass Transfer of a Three-Layer Impingement/Effusion Cooling System.
-
Creator
-
Smith, Brandon, Chow, Louis, Wu, Xinzhang, Deng, Weiwei, University of Central Florida
-
Abstract / Description
-
Cooling techniques for high density electrical components and electronic devices have been studied heavily in recent years. The advancements in the electrical/electronic industry have required methods of high heat flux removal. Many of the current electrical components and electronic devices produce a range of heat fluxes from 20 W/cm2 (-) 100 W/cm2. While parallel flow cooling systems have been used in the past, jet impingement is now more desirable for its potential to have a heat transfer...
Show moreCooling techniques for high density electrical components and electronic devices have been studied heavily in recent years. The advancements in the electrical/electronic industry have required methods of high heat flux removal. Many of the current electrical components and electronic devices produce a range of heat fluxes from 20 W/cm2 (-) 100 W/cm2. While parallel flow cooling systems have been used in the past, jet impingement is now more desirable for its potential to have a heat transfer coefficient 3-5 times greater than that of parallel flow at the same flow rate. Problems do arise when the jet impingement is confined and a cross flow develops that interacts with impinging jets downstream leading to a decrease in heat transfer coefficient. For long heated surfaces, such as an aircraft generator rotor, span wise fluid management is important in keeping the temperature distribution uniform along the length of the surface. A detailed simulation of the heat/mass transfer on a three-layer impingement/effusion cooling system has been conducted. The impingement jet fluid enters from the top layer into the bottom layer to impinge on the heated surface. The spent fluid is removed from the effusion holes and exits through the middle layer. Three different effusion configurations were used with effusion diameters ranging from 0.5 mm to 2 mm. Temperature uniformity, heat transfer coefficients, and pressure drops were compared for each effusion diameter arrangement, jet to target spacing (H/d), and rib configuration. A Shear Stress Transport (SST) turbulence fluid model was used within ANSYS CFX to simulate all design models. Three-layer configurations were also set in series for long, rectangular heated surfaces and compared against traditional cooling methods such as parallel internal flow and traditional jet impingement models. The results show that the three-layer design compared to a traditional impingement cooling scheme over an elongated heated surface can increase the average heat transfer coefficient by 75% and reduce the temperature difference on the surface by 75%. It was shown that for a three layer design under the same impingement geometry, the average heat transfer coefficient increases when H/d is small. The inclusion of ribs always provided better heat transfer and centralized the cooling areas. The heat transfer was increased by as much as 25% when ribs were used. The effusion hole arrangement showed minimal correlation to heat transfer other than a large array provides better results. The effusion holes' greatest impact was found in the pressure drop of the cooling model. The pressure losses were minimal when the effective area of effusion holes was large. This minimizes the losses due to contraction and expansion.
Show less
-
Date Issued
-
2012
-
Identifier
-
CFE0004795, ucf:49720
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0004795
-
-
Title
-
AN IMPROVED THERMOREGULATORY MODEL FOR COOLING GARMENT APPLICATIONS WITH TRANSIENT METABOLIC RATES.
-
Creator
-
Westin, Johan, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Current state-of-the-art thermoregulatory models do not predict body temperatures with the accuracies that are required for the development of automatic cooling control in liquid cooling garment (LCG) systems. Automatic cooling control would be beneficial in a variety of space, aviation, military, and industrial environments for optimizing cooling efficiency, for making LCGs as portable and practical as possible, for alleviating the individual from manual cooling control, and for improving...
Show moreCurrent state-of-the-art thermoregulatory models do not predict body temperatures with the accuracies that are required for the development of automatic cooling control in liquid cooling garment (LCG) systems. Automatic cooling control would be beneficial in a variety of space, aviation, military, and industrial environments for optimizing cooling efficiency, for making LCGs as portable and practical as possible, for alleviating the individual from manual cooling control, and for improving thermal comfort and cognitive performance. In this study, we adopt the Fiala thermoregulatory model, which has previously demonstrated state-of-the-art predictive abilities in air environments, for use in LCG environments. We validate the numerical formulation with analytical solutions to the bioheat equation, and find our model to be accurate and stable with a variety of different grid configurations. We then compare the thermoregulatory model's tissue temperature predictions with experimental data where individuals, equipped with an LCG, exercise according to a 700 W rectangular type activity schedule. The root mean square (RMS) deviation between the model response and the mean experimental group response is 0.16°C for the rectal temperature and 0.70°C for the mean skin temperature, which is within state-of-the-art variations. However, with a mean absolute body heat storage error (e_BHS_mean) of 9.7 W·h, the model fails to satisfy the ±6.5 W·h accuracy that is required for the automatic LCG cooling control development. In order to improve model predictions, we modify the blood flow dynamics of the thermoregulatory model. Instead of using step responses to changing requirements, we introduce exponential responses to the muscle blood flow and the vasoconstriction command. We find that such modifications have an insignificant effect on temperature predictions. However, a new vasoconstriction dependency, i.e. the rate of change of hypothalamus temperature weighted by the hypothalamus error signal (DThy·dThy/dt), proves to be an important signal that governs the thermoregulatory response during conditions of simultaneously increasing core and decreasing skin temperatures, which is a common scenario in LCG environments. With the new DThy·dThy/dt dependency in the vasoconstriction command, the e_BHS_mean for the exercise period is reduced by 59% (from 12.9 W·h to 5.2 W·h). Even though the new e_BHS_mean of 5.8 W·h for the total activity schedule is within the target accuracy of ±6.5 W·h, e_BHS fails to stay within the target accuracy during the entire activity schedule. With additional improvements to the central blood pool formulation, the LCG boundary condition, and the agreement between model set-points and actual experimental initial conditions, it seems possible to achieve the strict accuracy that is needed for automatic cooling control development.
Show less
-
Date Issued
-
2008
-
Identifier
-
CFE0002460, ucf:47707
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0002460
-
-
Title
-
CHARACTERIZATION OF AN INLINE ROW IMPINGEMENT CHANNEL FOR TURBINE BLADE COOLING APPLICATIONS.
-
Creator
-
Ricklick, Mark, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Gas turbines have become an intricate part of today's society. Besides powering practically all 200,000+ passenger aircraft in use today, they are also a predominate form of power generation when coupled with a generator. The fact that they are highly efficient, and capable of large power to weight ratios, makes gas turbines an ideal solution for many power requirement issues faced today. Designers have even been able to develop small, micro-turbines capable of producing efficient...
Show moreGas turbines have become an intricate part of today's society. Besides powering practically all 200,000+ passenger aircraft in use today, they are also a predominate form of power generation when coupled with a generator. The fact that they are highly efficient, and capable of large power to weight ratios, makes gas turbines an ideal solution for many power requirement issues faced today. Designers have even been able to develop small, micro-turbines capable of producing efficient portable power. Part of the turbine's success is the fact that their efficiency levels have continuously risen since their introduction in the early 1800's. Along with improvements in our understanding and designs of the aerodynamic components of the turbine, as well as improvements in the areas of material design and combustion control, advances in component cooling techniques have predominantly contributed to this success. This is the result of a simple thermodynamic concept; as the turbine inlet temperature is increased, the overall efficiency of the machine increases as well. Designers have exploited this fact to the extent that modern gas turbines produce rotor inlet temperatures beyond the melting point of the sophisticated materials used within them. This has only been possible through the use of sophisticated cooling techniques, particularly in the 1st stage vanes and blades. Some of the cooling techniques employed today have been internal cooling channels enhanced with various features, film and showerhead cooling, as well as internal impingement cooling scenarios. Impingement cooling has proven to be one of the most capable heat removal processes, and the combination of this cooling feature with that of channel flow, as is done in impingement channel cooling, creates a scenario that has understandably received a great deal of attention in recent years. This study has investigated several of the unpublished characteristics of these impingement channels, including the channel height effects on the performance of the channel side walls, effects of bulk temperature increase on heat transfer coefficients, circumferential heat variation effects, and effects on the uniformity of the heat transfer distribution. The main objectives of this dissertation are to explore the various previously unstudied characteristics of impingement channels, in order to sufficiently predict their performance in a wide range of applications. The potential exists, therefore, for a designer to develop a blade with cooling characteristics specifically tailored to the expected component thermal loads. Temperature sensitive paint (TSP) is one of several non-intrusive optical temperature measurements techniques that have gained a significant amount of popularity in the last decade. By employing the use of TSP, we have the ability to provide very accurate (less than 1 degree Celsius uncertainty), high resolution full-field temperature measurements. This has allowed us to investigate the local heat transfer characteristics of the various channel surfaces under a variety of steady state testing conditions. The comparison of thermal performance and uniformity for each impingement channel configuration then highlights the benefits and disadvantages of various configurations. Through these investigations, it has been shown that the channel side walls provide heat transfer coefficients comparable to those found on the target surface, especially at small impingement heights. Although the side walls suffer from highly non-uniform performance near the start of the channel, the profiles become very uniform as the cross flow develops and becomes a dominating contributor to the heat transfer coefficient. Increases in channel height result in increased non-uniformity in the streamwise direction and decreased heat transfer levels. Bulk temperature increases have also been shown to be an important consideration when investigating surfaces dominated by cross flow heat transfer effects, as enhancements up to 80% in some areas may be computed. Considerations of these bulk temperature changes also allow the determination of the point at which the flow transitions from an impingement dominated regime to one that is dominated by cross flow effects. Finally, circumferential heat variations have proven to have negligible effects on the calculated heat transfer coefficient, with the observed differences in heat transfer coefficient being contributed to the unaccounted variations in channel bulk temperature.
Show less
-
Date Issued
-
2009
-
Identifier
-
CFE0002955, ucf:47948
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0002955
-
-
Title
-
EFFECT OF PRESSURE GRADIENT AND WAKE ON ENDWALL FILM COOLING EFFECTIVENESS.
-
Creator
-
Rodriguez, Sylvette, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Endwall film cooling is a necessity in modern gas turbines for safe and reliable operation. Performance of endwall film cooling is strongly influenced by the hot gas flow field, among other factors. For example, aerodynamic design determines secondary flow vortices such as passage vortices and corner vortices in the endwall region. Moreover blockage presented by the leading edge of the airfoil subjects the incoming flow to a stagnating pressure gradient leading to roll-up of the approaching...
Show moreEndwall film cooling is a necessity in modern gas turbines for safe and reliable operation. Performance of endwall film cooling is strongly influenced by the hot gas flow field, among other factors. For example, aerodynamic design determines secondary flow vortices such as passage vortices and corner vortices in the endwall region. Moreover blockage presented by the leading edge of the airfoil subjects the incoming flow to a stagnating pressure gradient leading to roll-up of the approaching boundary layer and horseshoe vortices. In addition, for a number of heavy frame power generation gas turbines that use cannular combustors, the hot and turbulent gases exiting from the combustor are delivered to the first stage vane through transition ducts. Wakes induced by walls separating adjacent transition ducts located upstream of first row vanes also influence the entering main gas flow field. Furthermore, as hot gas enters vane passages, it accelerates around the vane airfoils. This flow acceleration causes significant streamline curvature and impacts lateral spreading endwall coolant films. Thus endwall flow field, especially those in utility gas turbines with cannular combustors, is quite complicated in the presence of vortices, wakes and strong favorable pressure gradient with resulting flow acceleration. These flow features can seriously impact film cooling performance and make difficult the prediction of film cooling in endwall. This study investigates endwall film cooling under the influence of pressure gradient effects due to stagnation region of an axisymmetric airfoil and in mainstream favorable pressure gradient. It also investigates the impact of wake on endwall film cooling near the stagnation region of an airfoil. The investigation consists of experimental testing and numerical simulation. Endwall film cooling effectiveness is investigated near the stagnation region on an airfoil by placing an axisymmetric airfoil downstream of a single row of inclined cylindrical holes. The holes are inclined at 35° with a length-to-diameter ratio of 7.5 and pitch-to-diameter ratio of 3. The ratio of leading edge radius to hole diameter and the ratio of maximum airfoil thickness to hole diameter are 6 and 20 respectively. The distance of the leading edge of the airfoil is varied along the streamwise direction to simulate the different film cooling rows preceding the leading edge of the airfoil. Wake effects are induced by placing a rectangular plate upstream of the injection point where the ratio of plate thickness to hole diameter is 6.4, and its distance is also varied to investigate the impact of strong and mild wake on endwall film cooling effectiveness. Blowing ratio ranged from 0.5 to 1.5. Film cooling effectiveness is also investigated under the presence of mainstream pressure gradient with converging main flow streamlines. The streamwise pressure distribution is attained by placing side inserts into the mainstream. The results are presented for five holes of staggered inclined cylindrical holes. The inclination angle is 30° and the tests were conducted at two Reynolds number, 5000 and 8000. Numerical analysis is employed to aid the understanding of the mainstream and coolant flow interaction. The solution of the computational domain is performed using FLUENT software package from Fluent, Inc. The use of second order schemes were used in this study to provide the highest accuracy available. This study employed the Realizable κ-ε model with enhance wall treatment for all its cases. Endwall temperature distribution is measured using Temperature Sensitive Paint (TSP) technique and film cooling effectiveness is calculated from the measurements and compared against numerical predictions. Results show that the characteristics of average film effectiveness near the stagnation region do not change drastically. However, as the blowing ratio is increased jet to jet interaction is enhanced due to higher jet spreading resulting in higher jet coverage. In the presence of wake, mixing of the jet with the mainstream is enhanced particularly for low M. The velocity deficit created by the wake forms a pair of vortices offset from the wake centerline. These vortices lift the jet off the wall promoting the interaction of the jet with the mainstream resulting in a lower effectiveness. The jet interaction with the mainstream causes the jet to lose its cooling capabilities more rapidly which leads to a more sudden decay in film effectiveness. When film is discharged into accelerating main flow with converging streamlines, row-to-row coolant flow rate is not uniform leading to varying blowing ratios and cooling performance. Jet to jet interaction is reduced and jet lift off is observed for rows with high blowing ratio resulting in lower effectiveness.
Show less
-
Date Issued
-
2008
-
Identifier
-
CFE0002425, ucf:47769
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0002425
-
-
Title
-
Planar Laser Induced Fluorescence Experiments and Modeling Study of Jets in Crossflow at Various Injection Angles.
-
Creator
-
Thompson, Luke, Vasu Sumathi, Subith, Kassab, Alain, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Planar Laser Induced Fluorescence (PLIF) with acetone seeding was applied to measure the scalar fields of an axisymmetric freejet and an inclined jet-in-crossflow as applicable to film cooling. From the scalar fields, jet-mixing and trajectory characteristics were obtained. In order to validate the technique, the canonical example of a nonreacting freejet of Reynolds Numbers 900-9000 was investigated. Desired structural characteristics were observed and showed strong agreement with...
Show morePlanar Laser Induced Fluorescence (PLIF) with acetone seeding was applied to measure the scalar fields of an axisymmetric freejet and an inclined jet-in-crossflow as applicable to film cooling. From the scalar fields, jet-mixing and trajectory characteristics were obtained. In order to validate the technique, the canonical example of a nonreacting freejet of Reynolds Numbers 900-9000 was investigated. Desired structural characteristics were observed and showed strong agreement with computational modeling. After validating the technique with the axisymmetric jet, the jet-in-crossflow was tested with various velocity ratios and jet injection angles. Results indicated the degree of wall separation for different injection angles and demonstrate both the time-averaged trajectories as well as select near-wall concentration results for varying jet momentum fluxes. Consistent with literature findings, the orthogonal jet trajectory for varying blowing ratios collapsed when scaled by the jet-to-freestream velocity ratio and hole diameter, rd. Similar collapsing was demonstrated in the case of a non-orthogonal jet. Computational Fluid Dynamic (CFD) simulations using the OpenFOAM software was used to compare predictions with select experimental cases, and yielded reasonable agreement. Insight into the importance and structure of the counter rotating vortex pair and general flow field turbulence was highlighted by cross validation between CFD and experimental results.
Show less
-
Date Issued
-
2015
-
Identifier
-
CFE0006057, ucf:50992
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0006057
-
-
Title
-
CONJUGATE HEAT TRANSFER ANALYSIS OF COMBINED REGENERATIVE AND DISCRETE FILM COOLING IN A ROCKET NOZZLE.
-
Creator
-
Pearce, Charlotte M, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Conjugate heat transfer analysis has been carried out on an 89kN thrust chamber in order to evaluate whether combined discrete film cooling and regenerative cooling in a rocket nozzle is feasible. Several cooling configurations were tested against a baseline design of regenerative cooling only. New designs include combined cooling channels with one row of discrete film cooling holes near the throat of the nozzle, and turbulated cooling channels combined with a row of discrete film cooling...
Show moreConjugate heat transfer analysis has been carried out on an 89kN thrust chamber in order to evaluate whether combined discrete film cooling and regenerative cooling in a rocket nozzle is feasible. Several cooling configurations were tested against a baseline design of regenerative cooling only. New designs include combined cooling channels with one row of discrete film cooling holes near the throat of the nozzle, and turbulated cooling channels combined with a row of discrete film cooling holes. Blowing ratio and channel mass flow rate were both varied for each design. The effectiveness of each configuration was measured via the maximum hot gas-side nozzle wall temperature, which can be correlated to number of cycles to failure. A target maximum temperature of 613K was chosen. Combined film and regenerative cooling, when compared to the baseline regenerative cooling, reduced the hot gas side wall temperature from 667K to 638K. After adding turbulators to the cooling channels, combined film and regenerative cooling reduced the temperature to 592K. Analysis shows that combined regenerative and film cooling is feasible with significant consequences, however further improvements are possible with the use of turbulators in the regenerative cooling channels.
Show less
-
Date Issued
-
2016
-
Identifier
-
CFH2000138, ucf:45923
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFH2000138
-
-
Title
-
Experimental and Numerical Study of Endwall Film Cooling.
-
Creator
-
Mahadevan, Srikrishna, Kapat, Jayanta, Verma, Shashi, Vasu Sumathi, Subith, Ahmed, Kareem, Shivamoggi, Bhimsen, University of Central Florida
-
Abstract / Description
-
This research work investigates the thermal performance of a film-cooled gas turbine endwall under two different mainstream flow conditions. In the first part of the research investigation, the effect of unsteady passing wakes on a film-cooled pitchwise-curved surface (representing an endwall without airfoils) was experimentally studied for heat transfer characteristics on a time-averaged basis. The temperature sensitive paint technique was used to obtain the local temperatures on the test...
Show moreThis research work investigates the thermal performance of a film-cooled gas turbine endwall under two different mainstream flow conditions. In the first part of the research investigation, the effect of unsteady passing wakes on a film-cooled pitchwise-curved surface (representing an endwall without airfoils) was experimentally studied for heat transfer characteristics on a time-averaged basis. The temperature sensitive paint technique was used to obtain the local temperatures on the test surface. The required heat flux input was provided using foil heaters. Discrete film injection was implemented on the test surface using cylindrical holes with a streamwise inclination angle of 35? and no compound angle relative to the mean approach velocity vector. The passing wakes increased the heat transfer coefficients at both the wake passing frequencies that were experimented. Due to the increasing film cooling jet turbulence and strong jet-mainstream interaction at higher blowing ratios, the heat transfer coefficients were amplified. A combination of film injection and unsteady passing wakes resulted in a maximum pitch-averaged and centerline heat transfer augmentation of ? 28% and 31.7% relative to the no wake and no film injection case. The second part of the research study involves an experimental and numerical analysis of secondary flow and coolant film interaction in a high subsonic annular cascade with a maximum isentropic throat Mach number of ? 0.68. Endwall (platform) thermal protection is provided using discrete cylindrical holes with a streamwise inclination angle of 30? and no compound angle relative to the mean approach velocity vector. The surface flow visualization on the inner endwall provided the location of the saddle point and the three-dimensional separation lines. Computational predictions showed that the leading-edge horseshoe vortex was confined to approximately 1.5% of the airfoil span for the no film injection case and intensified with low momentum film injection. At the highest blowing ratio, the film cooling jet weakened the horseshoe vortex at the leading-edge plane. The passage vortex was intensified with coolant injection at all blowing ratios. It was seen that increasing average blowing ratio improved the film effectiveness on the endwall. The discharge coefficients calculated for each film cooling hole indicated significant non-uniformity in the coolant discharge at lower blowing ratios and the strong dependence of discharge coefficients on the mainstream static pressure and the location of three-dimensional separation lines. Near the airfoil suction side, a region of coalesced film cooling jets providing close to uniform film coverage was observed, indicative of the mainstream acceleration and the influence of three-dimensional separation lines.
Show less
-
Date Issued
-
2015
-
Identifier
-
CFE0005973, ucf:50775
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0005973
-
-
Title
-
PRELIMINARY STUDY ON THE IMPACT OF IMPINGEMENT ON THE EFFECTIVENESS OF FILM COOLING IN THE PRESENCE OF GAS PATH PRESSURE GRADIENT.
-
Creator
-
Peravali, Anil, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Impingement is the most commonly used method of cooling in the hot stages of gas turbines. This is often combined with film cooling to further increase the cooling performance. The mainstream flow where in the coolant films discharge often has large stream wise pressure variations. All existing studies on coupled film and impingement cooling concentrated on the effect of the film depletion on the impingement heat transfer. This study investigates the impact of impingement on film cooling,...
Show moreImpingement is the most commonly used method of cooling in the hot stages of gas turbines. This is often combined with film cooling to further increase the cooling performance. The mainstream flow where in the coolant films discharge often has large stream wise pressure variations. All existing studies on coupled film and impingement cooling concentrated on the effect of the film depletion on the impingement heat transfer. This study investigates the impact of impingement on film cooling, where the jets impinging on a flat plate are depleted through arrays of film cooling holes in the presence of pressure gradient in the main gas path. The main characteristic of the test setup is that there is an impingement wall on the backside of the film effusion wall. The fluid used for both impingement flow and main flow is air. The impingement flow is heated as opposed to the usual practice of heating mainflow, and the array of film holes are configured under the impingement jet hole arrays such that there is no direct impingement on the film holes. The static pressure variations and Mach number (0.01 to 0.3) in the mainstream underneath the flat plate are controlled by inserts with varying flow area. The detailed temperature distribution on the film-covered surface is measured using the Temperature Sensitive Paint (TSP) technique, and film cooling effectiveness is calculated from the measurements. Results are presented for averaged impingement jet Reynolds numbers of 5000 and 8000. The effect of impingement on film effectiveness is studied by comparing the results from the two cases: one where film flow is directly supplied from a plenum and the other where the post- impingement flow is depleted through film effusion holes. The results are presented for cylindrical film cooling holes which are inclined at angles of 20 deg and 30 deg with respect to the target plate surface. The variation of the effectiveness of the film hole arrays along the mainstream are studied in detail. It is observed that the impingement through jet effects the pressure distribution on the target plate with film holes, which in turn affects the blowing rates of each row. The change in the blowing ratios because of a different pressure distribution on the impingement side of the target plate causes the effectiveness to change. From the results it is observed that the farther rows of impingement are affected by the pressure distribution underneath the film holes and have more flow through the film cooling rows, this increases the inlet flow of the films which increase the blowing ratios and in turn decreases the effectiveness of the film cooling holes. The pressure distribution and the change of effectiveness are studied in detail.
Show less
-
Date Issued
-
2006
-
Identifier
-
CFE0001445, ucf:47056
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0001445
-
-
Title
-
STUDY OF DISCHARGE COEFFICIENT AND TRENDS IN FILM COOLING EFFECTIVENESS OF CONICAL HOLES WITH INCREASING DIFFUSION ANGLES.
-
Creator
-
Zuniga, Humberto, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Previous studies indicate that increasing the diffusion angle in conical film-cooling holes leads to an improvement in their film cooling effectiveness. Discharge coefficient and film cooling effectiveness measurements are conducted to characterize this behavior. Part of the focus of this investigation is to find out how this trend develops and attempt to ascertain the optimum cone angle, if possible. Six test plates, each with one row of eight conical-shaped cooling holes of equal diffusion...
Show morePrevious studies indicate that increasing the diffusion angle in conical film-cooling holes leads to an improvement in their film cooling effectiveness. Discharge coefficient and film cooling effectiveness measurements are conducted to characterize this behavior. Part of the focus of this investigation is to find out how this trend develops and attempt to ascertain the optimum cone angle, if possible. Six test plates, each with one row of eight conical-shaped cooling holes of equal diffusion angles of 0, 1, 2, 3, 6, or 8º, with respect to the hole axis are used in this study. The ratios of the hole exit areas to the inlet areas range from 1 to 2.85. Coolant injection angle for all holes is at 35 degrees to the horizontal, in the direction of the main flow. Coefficients of discharge of all holes are reported under flow conditions. Temperature sensitive paint, TSP, is the technique used to find the temperature distribution downstream of the cooling holes and determine the laterally averaged film-cooling effectiveness. Data are obtained for blowing ratios ranging from 0.5 to 1.5, at a constant density ratio of 1.26. Results and trends are compared with established literature, which also recommends that a cylindrical entry length for diffused holes should be at least 4 diameters long. The effect that an added entry length has on the 3-degree conical plate's cooling effectiveness is also explored. Data are compared to baseline cylindrical holes, as well as to fan-shaped film holes found in open literature. Results indicate that the conical holes with larger diffusion angles provide strikingly even film protection and outperform fan shaped and cylindrical holes under certain conditions over extended downstream distances. Also, the addition of a cylindrical entry length to a conical hole, by providing a manageable metering diameter, should ease their usage while providing the full benefits of the conical geometry which may one day lead to numerous industrial applications.
Show less
-
Date Issued
-
2006
-
Identifier
-
CFE0001492, ucf:47087
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0001492
-
-
Title
-
A DYNAMIC MODEL OF THE HUMAN/COOLINGSYSTEM/CLOTHING/ENVIRONMENT SYSTEM.
-
Creator
-
pu, zhengxiang, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
The human body compensates well for moderate climatic heat stress, but artificial environments often block or overwhelm physiological defense mechanism. Personal protective equipment (PPE) is one of sources of heat stress. It protects individual from chemical, physical, or biological hazards, but the high thermal insulation and low vapor permeability of PPE may also lead to substantial heat stress. Personal cooling is widely used to alleviate heat stress, especially for those situations where...
Show moreThe human body compensates well for moderate climatic heat stress, but artificial environments often block or overwhelm physiological defense mechanism. Personal protective equipment (PPE) is one of sources of heat stress. It protects individual from chemical, physical, or biological hazards, but the high thermal insulation and low vapor permeability of PPE may also lead to substantial heat stress. Personal cooling is widely used to alleviate heat stress, especially for those situations where ambient environmental cooling is not economically viable or feasible. It is important to predict the physiological responses of a person wearing PPE with personal cooling to make sure that the individual is free of heat stress, as well as any additional discomfort that may occur. Air temperature, radiant temperature, humidity and air movement are the four basic environmental parameters that affect human response to thermal environments. Combined with the personal parameters of metabolic heat generated by human activity and clothing worn by a person, they provide the six fundamental factors which define human thermal environments. If personal cooling system is available, the fluid flow speed, cooling tube distribution density and fluid inlet temperature have significant effects on the human thermal comfort. It is impractical to evaluate the problem experimentally due to too many factors involved. A thermal model was developed to improve human body thermal comfort prediction. The system researched includes human body, personal cooling system, clothing and environment. An existing model of thermoregulation is taken as a starting point. Changes and additions are made to provide better prediction. Personal cooling model was developed and it includes liquid cooling model, air cooling model and ice cooling model. Thermal resistance networks for the cooling system are built up; additionally a combined model of heat and mass transfer from cooling garment through clothing to environment is developed and incorporated into the personal cooling model and thermoregulatory model. The control volume method is employed to carry out the numerical calculation. An example simulation is presented for extra-vehicular activities on Mars. The simulation results agree well with available experimental data, though a small discrepancy between simulation results and experimental data is observed during the beginning of the cooling process. Compared with a water cooling lumped model, the thermal model provides a much better prediction. For water cooling, parametric study shows that the cooling water inlet temperature and liner thermal resistance have great effects on the maximum exposure time; PPE resistance and cooling water flow rate do not have much impact on the maximum exposure time. For air cooling, cooling air flow rate, inlet temperature, relative humidity and liner resistance have great effects on the maximum exposure time.
Show less
-
Date Issued
-
2005
-
Identifier
-
CFE0000416, ucf:46407
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0000416
-
-
Title
-
STUDY OF HEAT TRANSFER CHARACTERISTICS OF IMPINGING AIR JET USING PRESSURE ANDN TEMPERATURE SENSITIVE LUMINESCENT PAINT.
-
Creator
-
Liu, Quan, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Luminescent coating measurement system is a relatively new technology for quantitative pressure and temperature measurement. Usually referred to as Pressure Sensitive Paint (PSP) and Temperature Sensitive Paint (TSP), luminescent coatings contain sensor molecules, which undergoes a luminescent transition when excited with light of proper wavelength. The reaction is pressure and/or temperature sensitive. The image of TSP or PSP coated model surface can be captured with a scientific grade...
Show moreLuminescent coating measurement system is a relatively new technology for quantitative pressure and temperature measurement. Usually referred to as Pressure Sensitive Paint (PSP) and Temperature Sensitive Paint (TSP), luminescent coatings contain sensor molecules, which undergoes a luminescent transition when excited with light of proper wavelength. The reaction is pressure and/or temperature sensitive. The image of TSP or PSP coated model surface can be captured with a scientific grade camera and then processed to obtain full field temperature and pressure distribution with very high fidelity. The preparation time of the technique is short. The measurement system offers an economic alternative to conventional testing methods using large number of pressure taps and thermocouples. The purpose of the experiment in this thesis is to take the benefits of the TSP and PSP technique, develop a well-controlled process and then apply the technique for a fundamental study on jet impingement heat transfer. First, Uni-Coat TSP and Binary-FIB PSP purchased from ISSI Inc. are calibrated to high accuracy. The calibration uncertainty of TSP and PSP are found to be ±0.93 °C and ±0.12 psi over temperature and pressure ranges of 22 to 90 ° C and 5 to 14.7 psia, respectively. The photodegradation of TSP is then investigated with the same calibration system. The photodegradation refers to the phenomenon of decreasing emission intensity as the luminescent paint is exposed to the illumination light during testing. It was found that photodegradation rate is a strong function of temperature and the optical power of illumination lighting. The correlation developed in this work is expected to compensate the degradation of TSP to achieve high measurement accuracy. Both TSP and PSP were then applied in the flow and heat transfer measurement of single round impinging air jet. Various separation distance (Z/D) and jet Reynolds number are tested. Pressure measurement on the jet impinged target surface using PSP clearly shows the boundary of jet impingement zone, which broadens with separation distance. In heat transfer experiment using TSP, the "second peak" in local heat transfer occurring at radial distance r/D around 2 is clearly observed when the separation distance Z/D is shorter than the length of jet potential core. The slight variation in radial location and the amplitude of the "second peak" are captured as Z/D and jet Reynolds number change. The optimum Z/D of stagnation point heat transfer is found to be around 5. The effect of jet nozzle configuration is investigated. It is found that the heat transfer rate associated with "tube jet" is generally higher than that of "plate jet". The difference in heat transfer between the two jet configurations is related to the weaker entrainment effect associated with "plate jet", where the entrainment of surrounding air is confined by the injection plate, especially under small Z/D circumstances. When compared with the benchmark data in the literature, the averaged heat transfer data of "tube jet" matches the empirical data better than those of "plate jet". The maximum difference is 3.3% for tube jet versus 15.4% for plate jet at Reynolds number of 60000 and Z/D of 5. The effect of surface roughness on jet impingement heat transfer is also studied. Heat transfer can be significantly increased by the enhanced roughness of the target surface. The largest roughness effect is achieved near stagnation point at high jet Reynolds number. Compared to the heat transfer to a smooth plate, as high as 30.9% increase in area-averaged Nusselt number is observed over a rough surface at r/D=1.5 and jet Reynolds number of 60000. The most significant advance of the present work is that both temperature and pressure measurement be obtained with the same measurement system and with accuracy comparable to traditional testing methods. The procedures that were employed in this work should be easy to apply in any university or industrial testing facility. It provides a rapid testing tool that can help solve complex problems in aerodynamics and heat transfer
Show less
-
Date Issued
-
2006
-
Identifier
-
CFE0000960, ucf:46747
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0000960
-
-
Title
-
Investigation into the Feasibility of Adding Turbulators to Rocket Combustion Chamber Cooling Channels Using a Conjugate Heat Transfer Analysis.
-
Creator
-
Buchanan, Tyler, Kapat, Jayanta, Raghavan, Seetha, Ghosh, Ranajay, University of Central Florida
-
Abstract / Description
-
A conjugate heat transfer analysis will be carried out to simulate an 89 kN thrust chamber hydrogen cooling channel, to determine the feasibility of adding turbulators to the combustion chamber cooling channels at various parameters such as angle, pitch, and height of the turbulator. An existing regeneratively cooled chamber environment is simulated and used as a baseline case to be compared against. The new design includes using ribbed turbulators or delta wedges in the cooling channels to...
Show moreA conjugate heat transfer analysis will be carried out to simulate an 89 kN thrust chamber hydrogen cooling channel, to determine the feasibility of adding turbulators to the combustion chamber cooling channels at various parameters such as angle, pitch, and height of the turbulator. An existing regeneratively cooled chamber environment is simulated and used as a baseline case to be compared against. The new design includes using ribbed turbulators or delta wedges in the cooling channels to increase the heat transfer on the channel hot wall (wall adjacent to the hot gas wall) and on the two channel sidewalls. With a higher heat transfer coefficient, the sidewalls behave like fins for heat transfer and participate more in the overall heat transfer process in the channel. Efficient rib and wedge geometries are chosen based on previous investigations. A conjugate heat transfer analysis is performed using a straight duct with the rib and wedge geometries included, with boundary conditions similar to those found in the combustion chamber, to provide thermal hydraulic performance data at numerous turbulator configurations. The baseline channel's maximum hot wall temperature is the target maximum hot wall temperature that is desired to be reduced. The goal is to reduce the hot gas side wall temperature at a minimal cost in pressure drop.
Show less
-
Date Issued
-
2018
-
Identifier
-
CFE0007160, ucf:52320
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0007160
-
-
Title
-
Surface Measurements and Predictions of Full-Coverage Film Cooling.
-
Creator
-
Natsui, Gregory, Kapat, Jayanta, Raghavan, Seetha, Vasu Sumathi, Subith, University of Central Florida
-
Abstract / Description
-
Full-coverage film cooling is investigated both experimentally and numerically. First,surface measurements local of adiabatic film cooling eeffectiveness and heat transfer augmentation for four different arrays are described. Reported next is a comparison between two very common turbulence models, Realizable k-epsilon and SST k-omega, and their ability to predict local film cooling effectiveness throughout a full-coverage array.The objective of the experimental study is the quantification of...
Show moreFull-coverage film cooling is investigated both experimentally and numerically. First,surface measurements local of adiabatic film cooling eeffectiveness and heat transfer augmentation for four different arrays are described. Reported next is a comparison between two very common turbulence models, Realizable k-epsilon and SST k-omega, and their ability to predict local film cooling effectiveness throughout a full-coverage array.The objective of the experimental study is the quantification of local heat transferaugmentation and adiabatic film cooling effectiveness for four surfaces cooled by large, both in hole count and in non-dimensional spacing, arrays of film cooling holes. The four arrays are of two different hole-to-hole spacings (P=D = X=D = 14.5; 19.8) and two different hole inclination angles (alpha = 30°; 45°), with cylindrical holes compounded relative to the flow(beta = 45°) and arranged in a staggered configuration. Arrays of up to 30 rows are tested so that the superposition effect of the coolant film can be studied. In addition, shortened arrays of up to 20 rows of coolant holes are also tested so that the decay of the coolant film following injection can be studied.Levels of laterally averaged effectiveness reach values as high as η = 0.5, and are not yet at the asymptotic limit even after 20 - 30 rows of injection for all cases studied. Levels of heat transfer augmentation asymptotically approach values of h=h0 ≈ 1.35 rather quickly, only after 10 rows. It is conjectured that the heat transfer augmentation levels off very quickly due to the boundary layer reaching an equilibrium in which the perturbation from additional film rows has reached a balance with the damping effect resulting from viscosity. The levels of laterally averaged adiabatic film cooling effectiveness far exceeding eta = 0.5 aremuch higher than expected. The heat transfer augmentation levels off quickly as opposed tothe film effectiveness which continues to rise (although asymptotically) at large row numbers. This ensures that an increased row count represents coolant well spent.The numerical predictions are carried out in order to test the ability of the two mostcommon turbulence models to properly predict full-coverage film cooling. The two models chosen, Realizable k-epsilon (RKE) and Shear Stress Transport k-omega (SSTKW), areboth two-equation models coupled with Reynolds Averaged governing equations which makeseveral gross physical assumptions and require several empirical values. Hence, the modelsare not expected to provide perfect results. However, very good average values are seen tobe obtained through these simple models. Using RKE in order to model full-coverage filmcooling will yield results with 30% less error than selecting SSTKW.
Show less
-
Date Issued
-
2012
-
Identifier
-
CFE0004580, ucf:49221
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0004580
-
-
Title
-
Heat Transfer and Friction Augmentation in a Narrow Rectangular Duct with Symmetrical and Non-Symmetrical Wedge-Shaped Turbulators.
-
Creator
-
Valentino, Michelle, Kapat, Jayanta, Deng, Weiwei, Kassab, Alain, University of Central Florida
-
Abstract / Description
-
The need for cleaner and more fuel efficient means to produce electricity is growing steadily. Advancements in cooling technologies contribute to the improvements in turbine efficiency and are used for gas turbines and for power generation in automotive, aviation, as well as in naval applications, and many more. Studies introducing turbulators on walls of internal cooling channels, which can be applied to hot gas components and in recuperative heat exchangers, have been reviewed for their...
Show moreThe need for cleaner and more fuel efficient means to produce electricity is growing steadily. Advancements in cooling technologies contribute to the improvements in turbine efficiency and are used for gas turbines and for power generation in automotive, aviation, as well as in naval applications, and many more. Studies introducing turbulators on walls of internal cooling channels, which can be applied to hot gas components and in recuperative heat exchangers, have been reviewed for their ability to promote heat transfer in the channel while observing pressure loss caused by adding the features. Several types of turbulators have been studied; ribs, pin fins, dimples, wedges, and scales are some examples of features that have been added to walls of internal cooling channels or heat exchangers to increase heat transfer. This study focuses on two types of wedge turbulator designs, a full symmetrical wedge and a half, or non-symmetrical right-triangular wedge for the purpose of disrupting the thermal boundary layer close to hot walls without causing large-scale mixing and pressure drops. There are two sizes of the wedges, the first set of full and half wedges have an e/Dh=0.10 with the second at e/Dh=0.40, a feature that fills the height of the boundary layer. There are six cases studied, two one-wall and four two-wall cases in a 2:1 aspect ratio channel at Reynolds numbers of 10,000, 20,000, 30,000, and 40,000. Two experimental setups are utilized: a segmented copper block and transient TLC, along with numerical simulation for computational flow visualization. Wall temperature data is collected from all four walls for the copper experimental setup and three walls on the transient TLC setup. The fourth wall of the acrylic test section for the transient TLC tests is utilized for pressure testing, where static pressure ports are placed along the side wall. Although the small features did not show large influence in heat transfer on the side walls as much as the larger features or as high of heat transfer on the featured walls, the minimal pressure loss in the channel kept overall thermal performance of the small two wall full wedge features very high. The case of the large half wedge on two walls also showed very high thermal performance, having pressure loss values nearly half of the same sized (length and height) full wedge feature while having the ability to incorporate side walls into the overall heat transfer enhancement. The results found in the experimental setups are supported by the visualization of flow characteristics from the numerical testing. Comparing the initial wedge study to recent full rib studies show the wedges have similar improvements in heat transfer to the full rib cases with friction augmentations 5 to 10 times lower than the full rib cases. Further improvements to wedge heat transfer and pressure drop can be done by determining optimal wedge size and orientation.
Show less
-
Date Issued
-
2011
-
Identifier
-
CFE0004489, ucf:49299
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0004489
-
-
Title
-
Decentralized Consensus-based Control Allocation For Some Dynamical Systems.
-
Creator
-
Mark, August, Xu, Yunjun, Gou, Jihua, Lin, Kuo-Chi, University of Central Florida
-
Abstract / Description
-
In this dissertation, three separate studies, wherein techniques from graph theory and consensus control are used to address control allocation problems, are presented. In the first study, a decentralized allocator is presented for synthetic jet actuators and control surfaces onboard a small unmanned aerial vehicle to cooperatively generate desired aerodynamic moments. First order linear dynamics are assumed for both the synthetic jet actuators and control surfaces. A weighted consensus...
Show moreIn this dissertation, three separate studies, wherein techniques from graph theory and consensus control are used to address control allocation problems, are presented. In the first study, a decentralized allocator is presented for synthetic jet actuators and control surfaces onboard a small unmanned aerial vehicle to cooperatively generate desired aerodynamic moments. First order linear dynamics are assumed for both the synthetic jet actuators and control surfaces. A weighted consensus algorithm with limited feedback is used for the aerodynamic moment contribution allocator considering constraints. In the second study, the same allocation problem as in the first study is considered, but the actuator dynamics are now assumed to behave according to second order nonlinear dynamics. In the third study, a spray allocator is presented for an array of nozzles used to cool a large heated surface in order to address the local disagreement in surface temperature within sprayed sections. Within each study, the stability of each system is proven, and the performance of each allocator is demonstrated via simulations.
Show less
-
Date Issued
-
2019
-
Identifier
-
CFE0007496, ucf:52636
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0007496
-
-
Title
-
A Full Coverage Film Cooling Study: The Effect of an Alternating Compound Angle.
-
Creator
-
Hodges, Justin, Kapat, Jayanta, Gordon, Ali, Vasu Sumathi, Subith, University of Central Florida
-
Abstract / Description
-
This thesis is an experimental and numerical full-coverage film cooling study. The objective of this work is the quantification of local heat transfer augmentation and adiabatic film cooling effectiveness for two full-coverage film cooling geometries. Experimental data was acquired with a scientific grade CCD camera, where images are taken over the heat transfer surface, which is painted with a temperature sensitive paint. The CFD component of this study served to evaluate how well the v2-f...
Show moreThis thesis is an experimental and numerical full-coverage film cooling study. The objective of this work is the quantification of local heat transfer augmentation and adiabatic film cooling effectiveness for two full-coverage film cooling geometries. Experimental data was acquired with a scientific grade CCD camera, where images are taken over the heat transfer surface, which is painted with a temperature sensitive paint. The CFD component of this study served to evaluate how well the v2-f turbulence model predicted film cooling effectiveness throughout the array, as compared with experimental data. The two staggered arrays tested are different from one another through a compound angle shift after 12 rows of holes. The compound angle shifts from ?=-45(&)deg; to ?=+45(&)deg; at row 13. Each geometry had 22 rows of cylindrical film cooling holes with identical axial and lateral spacing (X/D=P/D=23). Levels of laterally averaged film cooling effectiveness for the superior geometry approach 0.20, where the compound angle shift causes a decrease in film cooling effectiveness. Levels of heat transfer augmentation maintain values of nearly h/h0=1.2. There is no effect of compound angle shift on heat transfer augmentation observed. The CFD results are used to investigate the detrimental effect of the compound angle shift, while the SST k-? turbulence model shows to provide the best agreement with experimental results.
Show less
-
Date Issued
-
2015
-
Identifier
-
CFE0005626, ucf:50228
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0005626
-
-
Title
-
HEAT TRANSFER STUDY OF A TRIPLE ROW IMPINGEMENT CHANNEL AT LARGE IMPINGEMENT HEIGHTS.
-
Creator
-
Claretti, Roberto, Kapat, Jayanta, University of Central Florida
-
Abstract / Description
-
Advanced cooling techniques are required to increase the Brayton cycle temperature ratio necessary for the increase of the overall cycle's efficiency. Current turbine components are cooled with an array of internal cooling channels in the midchord section of the blade, pin fin arrays at the trailing edge and impingement channels in the leading edge. Impingement channels provide the designer with high convective coefficients on the target surface. Increasing the heat transfer coefficient of...
Show moreAdvanced cooling techniques are required to increase the Brayton cycle temperature ratio necessary for the increase of the overall cycle's efficiency. Current turbine components are cooled with an array of internal cooling channels in the midchord section of the blade, pin fin arrays at the trailing edge and impingement channels in the leading edge. Impingement channels provide the designer with high convective coefficients on the target surface. Increasing the heat transfer coefficient of these channels has been a subject of research for the past 20 years. In the current study, a triple row impingement channel is studied with a jet to target spacing of 6, 8 and 10. The effects of sidewalls are also analyzed. Temperature sensitive paint alongside thin foil heaters are used to obtain heat transfer distributions throughout the target and side walls of the three different channels. Thermal performances were also calculated for the two largest channels. It was found that the side walls provide a significant amount of cooling especially when the channels are mounted side by side so that their sidewalls behave as fins. Similar to literature it was found that an increase in Z/D decreases heat transfer coefficient and provides a more uniform profile. It was also found that the Z/D = 6 and 8 target wall heat transfer profiles are very similar, hinting to the fact that successful potential core impingement may have occurred at height of eight diameters. A Computational Fluid Dynamics, or CFD, study was also performed to provide better insight into the flow field that creates such characteristic heat transfer profiles. The Realizable k-µ solution with enhanced wall functions gave surface heat transfer coefficients 30% off from the experimental data.
Show less
-
Date Issued
-
2011
-
Identifier
-
CFH0003839, ucf:44763
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFH0003839
-
-
Title
-
Experimental and numerical investigation of a novel adsorption bed design for cooling applications.
-
Creator
-
Abdelhady, Ramy, Chow, Louis, Mansy, Hansen, Das, Tuhin, Duranceau, Steven, University of Central Florida
-
Abstract / Description
-
A global challenge is to develop environmentally friendly, affordable, compact and sustainable technologies to provide heating and cooling power. Adsorption cooling (AC) technology is one of the most promising ways to solve the environmental issues and cut down the energy consumption related to the traditional air conditioning and refrigeration systems. However, AC systems still suffer from poor heat and mass transfer inside the adsorption bed, which is the main obstacle to commercialization...
Show moreA global challenge is to develop environmentally friendly, affordable, compact and sustainable technologies to provide heating and cooling power. Adsorption cooling (AC) technology is one of the most promising ways to solve the environmental issues and cut down the energy consumption related to the traditional air conditioning and refrigeration systems. However, AC systems still suffer from poor heat and mass transfer inside the adsorption bed, which is the main obstacle to commercialization of adsorption cooling units. The main goal of this study is designing an efficient adsorption cooling cycle. In this research work, an in-depth scaling analysis of heat and mass transfer in an adsorption packed bed has been performed to identify and quantify how the effective thermal diffusivity of an adsorption bed and the surface diffusion rate of an adsorbate in a nanoporous adsorbent affect the specific cooling power of an adsorption cooling system. The main goal of this study is to derive new scaling parameters that can be used to specify the optimal bed dimensions and select the appropriate adsorbate/adsorbent pair to achieve the maximum cooling power. As the choice of a suitable working pair is critical for an adsorption cooling cycle, an experimental setup is designed and built to measure the adsorption kinetics and isotherms of any working pair accurately. This setup is also able to measure the dynamic performance of an adsorption bed. The equilibrium uptakes of Fuji silica-gels Type-RD and RD-2060 (manufactured by Fuji Silysia, Japan), which are commonly used in adsorption cooling systems, are measured experimentally. Based on the adsorption rate and the adsorbent temperature measured simultaneously, a new approach is proposed to measure the surface diffusivity in the temperature and pressure ranges typical of those during the operating conditions of adsorption cooling systems. In addition, the experimental measurements from the lab-scale adsorption bed are used to validate the numerical models that are commonly used for estimating the SCP of AC cycle. By using the scaling parameters driven from the scaling analysis, a newly designed packed bed for use in AC systems is proposed and evaluated in this research. The proposed design consists of repeated packed bed cells (modules). Each module is an open-cell aluminum foam packed with silica gel to enhance the overall thermal conductivity of the bed from 0.198 to 5.8 W/m.K. the experimental test rig is used to evaluate the performance on the new adsorption bed. The effect of pores per inch (PPI) of the foam, silica-gel particle size, bed height and adsorption isotherm of different types of silica gel on the bed performance are investigated.
Show less
-
Date Issued
-
2019
-
Identifier
-
CFE0007422, ucf:52702
-
Format
-
Document (PDF)
-
PURL
-
http://purl.flvc.org/ucf/fd/CFE0007422
Pages