- Evaluating Corrosion Control Alternatives for a Reverse Osmosis, Nanofiltration and Anion-Exchange Blended Water Supply.
- Creator
-
Wilder, Rebecca, Duranceau, Steven, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
The research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced...
Show moreThe research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced DBP formation potential, integration of the NF process altered finished water quality parameters including pH, alkalinity and hardness. There was concern that these changes could result in secondary impacts related to accelerated corrosion of distribution system components and subsequent regulatory compliance. In addition, replacement of the LS process altered the in-plant blending operations by creating an unstable intermediate blend composed of RO and IX waters. There were concerns that this intermediate blend was affecting the integrity of in-plant hydraulic conveyance components.UCF developed a corrosion monitoring study to assess the potential impacts related to internal corrosion, water quality and regulatory compliance after integrating NF into the existing water supply. The intended purpose was to further highlight the complexities of corrosion, describe a unique approach to corrosion monitoring as well as offer various recommendations for corrosion control in a system that relies on a blended water supply. Research was conducted in three phases to address the in-plant and distribution system corrosion issues separately and identify appropriate corrosion control treatment alternatives. The three test phases included: a baseline conditions assessment to compare corrosion of the intermediate RO-IX blend with the finished water blend (RO-IX-NF); an in-plant corrosion control evaluation; and a distribution system corrosion control evaluation.A test apparatus was constructed and operated at the Town's facilities to monitor corrosion activity of mild steel, copper and lead solder metal components. The test apparatus consisted of looped PVC pipe segments housed with electrochemical probes and metal coupons to monitor corrosion rates of the metallic components. Electrochemical probes containing metal electrodes were used to obtain instantaneous corrosion rates by means of the Linear Polarization Resistance (LPR) technique while the metal coupons were gravimetrically evaluated for weight loss. The electrochemical probes permitted daily monitoring of each metal's corrosion rates while metal coupons were analyzed at the conclusion of testing and used for comparison. Different test waters flowed through the corrosion rack according to each test phase and relative corrosion rates were compared to evaluate corrosion control techniques.Study findings indicated that the intermediate blend was more corrosive, in general, then the final blend; however, research also indicated that the final blend of water was increasing lead and copper concentrations within the distribution system. An orthophosphate corrosion inhibitor was evaluated for in-plant corrosion control. The inhibitor's performance was assessed by comparing mild steel corrosion rates with and without the chemical. In addition, secondary impacts related to introduction of the chemical were evaluated by pre-corroding the metallic components prior to the introduction of the inhibitor. Results indicated that the inhibitor marginally decreased corrosion rates and increased the turbidity of the water supply. Based on these observations, it was concluded that the inhibitor was not a viable solution for in-plant corrosion control. To resolve in-plant corrosion issues, recommendations were made for modification of in-plant blending operations to eliminate the corrosive intermediate blend from the process allowing the RO, IX and NF treated waters to be blended in a common location. The effectiveness of a poly/ortho blended phosphate chemical inhibitor was evaluated for reducing lead and copper corrosion to resolve distribution corrosion issues. A 50/50 poly/ortho blend was selected because of its analogous use in similar municipal water facilities. Metallic corrosion rates, particularly lead and copper, were compared with and without the inhibitor to assess the performance of the chemical. Like the previous test phase, the metallic components were pre-corroded prior to the chemical's introduction to determine if secondary impacts could result from its presence. Results indicated that lead and copper corrosion rates were lower in the presence of the inhibitor, and secondary impacts related to increased turbidity were not observed for this chemical. Based on these results, it was recommended that a poly/ortho blended phosphate be used to decrease lead and copper corrosion within the Town's distribution system.
Show less - Date Issued
- 2012
- Identifier
- CFE0004460, ucf:49349
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004460
- Title
- IMPACT OF ZINC ORTHOPHOSPHATE INHIBITOR ONDISTRIBUTION SYSTEM WATER QUALITY.
- Creator
-
Guan, Xiaotao, Taylor, James, University of Central Florida
- Abstract / Description
-
This dissertation consists of four papers concerning impacts of zinc orthophosphate (ZOP) inhibitor on iron, copper and lead release in a changing water quality environment. The mechanism of zinc orthophosphate corrosion inhibition in drinking water municipal and home distribution systems and the role of zinc were investigated. Fourteen pilot distribution systems (PDSs) which were identical and consisted of increments of PVC, lined cast iron, unlined cast iron and galvanized steel pipes were...
Show moreThis dissertation consists of four papers concerning impacts of zinc orthophosphate (ZOP) inhibitor on iron, copper and lead release in a changing water quality environment. The mechanism of zinc orthophosphate corrosion inhibition in drinking water municipal and home distribution systems and the role of zinc were investigated. Fourteen pilot distribution systems (PDSs) which were identical and consisted of increments of PVC, lined cast iron, unlined cast iron and galvanized steel pipes were used in this study. Changing quarterly blends of finished ground, surface and desalinated waters were fed into the pilot distribution systems over a one year period. Zinc orthophosphate inhibitor at three different doses was applied to three PDSs. Water quality and iron, copper and lead scale formation was monitored for the one year study duration. The first article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on surface characteristics of iron corrosion products in a changing water quality environment. Surface compositions of iron surface scales for iron and galvanized steel coupons incubated in different blended waters in the presence of ZOP inhibitor were investigated using X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM) / Energy Dispersive X-ray Spectroscopy (EDS). Based on surface characterization, predictive equilibrium models were developed to describe the controlling solid phase and mechanism of ZOP inhibition and the role of zinc for iron release. The second article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total iron release in a changing water quality environment. Development of empirical models as a function of water quality and ZOP inhibitor dose for total iron release and mass balances analysis for total zinc and total phosphorus data provided insight into the mechanism of ZOP corrosion inhibition regarding iron release in drinking water distribution systems. The third article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total copper release in a changing water quality environment. Empirical model development was undertaken for prediction of total copper release as a function of water quality and inhibitor dose. Thermodynamic models for dissolved copper based on surface characterization of scale that were generated on copper coupons exposed to ZOP inhibitor were also developed. Surface composition was determined by X-ray Photoelectron Spectroscopy (XPS). The fourth article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total lead release in a changing water quality environment. Surface characterization of lead scale on coupons exposed to ZOP inhibitor by X-ray Photoelectron Spectroscopy (XPS) was utilized to identify scale composition. Development of thermodynamic model for lead release based on surface analysis results provided insight into the mechanism of ZOP inhibition and the role of zinc.
Show less - Date Issued
- 2007
- Identifier
- CFE0001931, ucf:47453
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0001931
- Title
- Control of Metal-Release and Tuberculation in a Silica-Laden Groundwater Distribution System on the Volcanic Island of Lana'i.
- Creator
-
Myers, Samantha, Duranceau, Steven, Sadmani, A H M Anwar, Lee, Woo Hyoung, University of Central Florida
- Abstract / Description
-
A corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several...
Show moreA corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several groundwater wells feed each of the WDS's; however, water quality between wells varies. Well water supplied to the WDS's is generally of high quality, therefore, the historical treatment method has been limited to disinfection prior to distribution. The distribution system consists of several materials of construction, which includes galvanized iron. Valves and pipes within the WDS were experiencing visible corrosion and tuberculation believed to be responsible for variable pressure drop throughout portions of the system.In this work, two corrosion racks, each consisting of two parallel loops, were designed, constructed, and installed at each site. One loop was maintained as a control while the other loop was used for testing alternative corrosion inhibitors. The racks utilized metal sample coupons and linear polarization resistance probes to provide data on corrosion rates of selected metals of interest.Results indicated that the water in Manele Bay experienced no noticeable change between the test loop and control loop when a corrosion inhibitor was added. A first experiment found the corrosion rates reached baseline steady(-)state at 4,000 operational hours. A second experiment found that the corrosion rates reached baseline steady(-)state at 2,200 operational hours. During these two experiments, the addition of a phosphate or silica(-)based inhibitor neither reduced nor increased the corrosion rates of mild steel, lead, and copper.Results from Lana'i City indicated that inhibitors offered little to no positive effect between the control condition and the test condition. During the first experiment, baseline corrosion was reached after 2,400 hours. The addition of a phosphate inhibitor did not reduce nor increase the corrosion rates of mild steel and lead. However, the corrosion rate of copper increased to 1.0mpy from 0.22mpy. The corrosion rate remained elevated after inhibitor feed was terminated. The second experiment reached baseline corrosion rates at 1,400 operational hours. The use of silica inhibitor neither reduced nor increased the corrosion rate of mil steel, lead, and copper.Since corrosion inhibitors were found to be ineffective, a valve exercise and replacement program for Pulama's assets was recommended. This program included: (1) developing a detailed asset inventory, (2) implementing operation and maintenance tasks, (3) forming a valve replacement plan, and (4) establishing long range financial planning. An opinion of probable replacement cost for 200 new valves was conceptually estimated to approximate 3.3 million dollars expended over a 20 year time frame.
Show less - Date Issued
- 2016
- Identifier
- CFE0006152, ucf:51152
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0006152
- Title
- THE EFFECTS OF PHOSPHATE AND SILICATE INHIBITORS ON SURFACE ROUGHNESS AND COPPER RELEASE IN WATER DISTRIBUTION SYSTEMS.
- Creator
-
MacNevin, David, Taylor, James, University of Central Florida
- Abstract / Description
-
The effects of corrosion inhibitors on water quality and the distribution system were studied. This dissertation investigates the effect of inhibitors on iron surface roughness, copper surface roughness, and copper release. Corrosion inhibitors included blended poly/ortho phosphate, sodium orthophosphate, zinc orthophosphate, and sodium silicate. These inhibitors were added to a blend of surface water, groundwater, and desalinated brackish water. Surface roughness of galvanized iron, unlined...
Show moreThe effects of corrosion inhibitors on water quality and the distribution system were studied. This dissertation investigates the effect of inhibitors on iron surface roughness, copper surface roughness, and copper release. Corrosion inhibitors included blended poly/ortho phosphate, sodium orthophosphate, zinc orthophosphate, and sodium silicate. These inhibitors were added to a blend of surface water, groundwater, and desalinated brackish water. Surface roughness of galvanized iron, unlined cast iron, lined cast iron, and polyvinyl chloride was measured using pipe coupons exposed for three months. Roughness of each pipe coupon was measured with an optical surface profiler before and after exposure to inhibitors. For most materials, inhibitor did not have a significant effect on surface roughness; instead, the most significant factor determining the final surface roughness was the initial surface roughness. Coupons with low initial surface roughness tended to have an increase in surface roughness during exposure, and vice versa, implying that surface roughness tended to regress towards an average or equilibrium value. For unlined cast iron, increased alkalinity and increased temperature tended to correspond with increases in surface roughness. Unlined cast iron coupons receiving phosphate inhibitors were more likely to have a significant change in surface roughness, suggesting that phosphate inhibitors affect stability of iron pipe scales. Similar roughness data collected with new copper coupons showed that elevated orthophosphate, alkalinity, and temperature were all factors associated with increased copper surface roughness. The greatest increases in surface roughness were observed with copper coupons receiving phosphate inhibitors. Smaller increases were observed with copper coupons receiving silicate inhibitor or no inhibitor. With phosphate inhibitors, elevated temperature and alkalinity were associated with larger increases in surface roughness and blue-green copper (II) scales.. Otherwise a compact, dull red copper (I) scale was observed. These data suggest that phosphate inhibitor addition corresponds with changes in surface morphology, and surface composition, including the oxidation state of copper solids. The effects of corrosion inhibitors on copper surface chemistry and cuprosolvency were investigated. Most copper scales had X-ray photoelectron spectroscopy binding energies consistent with a mixture of Cu2O, CuO, Cu(OH)2, and other copper (II) salts. Orthophosphate and silica were detected on copper surfaces exposed to each inhibitor. All phosphate and silicate inhibitors reduced copper release relative to the no inhibitor treatments, keeping total copper below the 1.3 mg/L MCLG for all water quality blends. All three kinds of phosphate inhibitors, when added at 1 mg/L as P, corresponded with a 60% reduction in copper release relative to the no inhibitor control. On average, this percent reduction was consistent across varying water quality conditions in all four phases. Similarly when silicate inhibitor was added at 6 mg/L as SiO2, this corresponded with a 25-40% reduction in copper release relative to the no inhibitor control. Hence, on average, for the given inhibitors and doses, phosphate inhibitors provided more predictable control of copper release across changing water quality conditions. A plot of cupric ion concentration versus orthophosphate concentration showed a decrease in copper release consistent with mechanistic control by either cupric phosphate solubility or a diffusion limiting phosphate film. Thermodynamic models were developed to identify feasible controlling solids. For the no inhibitor treatment, Cu(OH)2 provided the closest prediction of copper release. With phosphate inhibitors both Cu(OH)2 and Cu(PO4)·2H2O models provided plausible predictions. Similarly, with silicate inhibitor, the Cu(OH)2 and CuSiO3·H2O models provided plausible predictions.
Show less - Date Issued
- 2008
- Identifier
- CFE0002001, ucf:47621
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002001
- Title
- Assessment of a Surface Water Supply for Source and Treated Distribution System Quality.
- Creator
-
Rodriguez, Angela, Duranceau, Steven, Lee, Woo Hyoung, Sadmani, A H M Anwar, University of Central Florida
- Abstract / Description
-
This study focused on providing a source to tap assessment of surface water systems with respect to (i) the use of alternative biomonitoring tools, (ii) disinfection byproduct (DBP) formation and control, and (iii) corrosion control. In the first study component, two water systems were microbiologically evaluated using adenosine triphosphate (ATP) bioluminescence technology. It was determined that microbial ATP was useful as a surrogate for biomonitoring within a surface water system when...
Show moreThis study focused on providing a source to tap assessment of surface water systems with respect to (i) the use of alternative biomonitoring tools, (ii) disinfection byproduct (DBP) formation and control, and (iii) corrosion control. In the first study component, two water systems were microbiologically evaluated using adenosine triphosphate (ATP) bioluminescence technology. It was determined that microbial ATP was useful as a surrogate for biomonitoring within a surface water system when paired with traditional methods. Although microbial activity differed between distribution systems that used either chloramine or chlorine disinfectant, in both cases flowrate and season affected microbial ATP values. In the second study component, total trihalomethanes (TTHM) and haloacetic acids (HAA5) DBP formation and disinfectant stability was investigated using a novel DBP control process. The method relied on a combination of sulfate, ultraviolet light irradiation, pH, and aeration unit operations. Results indicate respective decreases in 7-day TTHM and HAA5 formation potentials of 36% - 57% and 20% - 47% for the surface waters investigated. In the third component of this work, a corrosion study assessed the effect of disinfectant chemical transitions on the corrosion rates of common distribution system metals. When a chlorine based disinfection system transitioned between chlorine and chloramine, mild steel corrosion increased by 0.45 mils per year (mpy) under chloramine and returned to baseline corrosion rates under chlorine. However, when a chloramine based disinfection system transitioned between chloramine and chlorine, mild steel corrosion increased in tandem with total chlorine levels. Unlike the chlorine system, the mild steel corrosion rates did not return to baseline under chloramine after exposure to 5 mg/L of total chlorine. Surface water systems should consider the use of ATP as a surrogate for biomonitoring, consider the novel treatment process for DBP formation control, and consider corrosion control in disinfectant decision-making activities.
Show less - Date Issued
- 2019
- Identifier
- CFE0007901, ucf:52751
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0007901