Current Search: Optical Parametric Oscillator (x)
View All Items
- Title
- DEVELOPMENT OF A COMPACT BROADBAND OPTICAL PARAMETRIC OSCILLATOR FOR ULTRA-SENSITIVE MOLECULAR DETECTION.
- Creator
-
Crystal, Sean O, Vodopyanov, Konstantin L., University of Central Florida
- Abstract / Description
-
Every gas molecule has a unique absorption spectrum that can be captured using optical spectroscopy to identify an unknown sample's composition. Frequency combs systems can provide an extremely broad mid-infrared spectrum that is very useful for molecular detection. A degenerate optical parametric oscillator (OPO) was built to generate the down-converted and shifted frequency comb spectrum. This system utilizes an ultra-short pulse 1.56�m pump laser and a never before used orientation...
Show moreEvery gas molecule has a unique absorption spectrum that can be captured using optical spectroscopy to identify an unknown sample's composition. Frequency combs systems can provide an extremely broad mid-infrared spectrum that is very useful for molecular detection. A degenerate optical parametric oscillator (OPO) was built to generate the down-converted and shifted frequency comb spectrum. This system utilizes an ultra-short pulse 1.56�m pump laser and a never before used orientation patterned gallium-phosphide crystal. Periodically polled lithium niobate (PPLN), Gallium Arsenide (GaAs) and Gallium Phosphide are all crystals used to accomplish this task. GaP, in comparison to PPLN, has (i) a larger nonlinear coefficient, (ii) much deeper infrared transparency, and (iii) smaller group dispersion � to allow for achieving broad spectral coverage. GaP also has a larger band gap than GaAs; therefore it can still be pumped with a standard telecom C-band laser. An octave-wide spanning frequency comb system was achieved and the characterization of the system is presented. This system is specifically designed to be compact and portable for initial experimental testing in the applications of medical breath analysis and combustion gas investigation.
Show less - Date Issued
- 2017
- Identifier
- CFH2000274, ucf:45837
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFH2000274
- Title
- Phase-locking Stability of a Quasi-single-cycle Pulse.
- Creator
-
Bodnar, Nathan, Richardson, Martin, Chang, Zenghu, Delfyett, Peter, University of Central Florida
- Abstract / Description
-
There is increasing interest in the generation of very short laser pulses, even down to attosecond (10-18 s) durations. Laser systems with femtosecond pulse durations are needed for these applications. For many of these applications, positioning of the maximum electric field within the pulse envelope can affect the outcome. The peak of the electric field relative to the peak of the pulse is called the Carrier Envelope Phase (CEP). Controlling the position of the electric field becomes more...
Show moreThere is increasing interest in the generation of very short laser pulses, even down to attosecond (10-18 s) durations. Laser systems with femtosecond pulse durations are needed for these applications. For many of these applications, positioning of the maximum electric field within the pulse envelope can affect the outcome. The peak of the electric field relative to the peak of the pulse is called the Carrier Envelope Phase (CEP). Controlling the position of the electric field becomes more important when pulse duration approaches single-cycle.This thesis focuses on the stabilization of a quasi-single-cycle laser facility. Improvements to this already-established laser facility, HERACLES (High Energy, Repetition rate Adjustable, Carrier-Locked-to-Envelope System) described in this thesis include a stabilized pump line and the improvement in CEP stabilization electronics. HERACLES is built upon an Optical Parametric Chirped Pulse Amplification (OPCPA) architecture. This architecture uses Optical Parametric Amplification (OPA) as the gain material to increase the output energy of the system. OPA relies on a nonlinear process to generate high gain (106) with ultra-wide bandwidth. Instabilities in the OPA driving pump energy can create dynamically fluctuations in the final OPCPA output energy. To reduce these fluctuations two key upgrades were implemented on the pump beam. Both were major improvements in the stability. Firstly, an improved regenerative amplifier design reduced beam pointing fluctuations. Secondly, the addition of a pump monitoring system with feedback-control eliminated long-term power drifts. Both enhanced the OPA pulse-to-pulse and long-term stability.To improve the stability in measuring CEP drifts, modification of the feedback electronics was needed. The modification consisted of integrating noise reduction electronics. This novel noise reducer uses a similar process to a super-heterodyne receiver. The noise reducer resulted in 60 dB reduction of out-of-band noise. This led to increased signal quality with cleaner amplification of weaker signals. The enhanced signal quality led to more reliable long-term locking. The synthetically increased signal-to-noise ratio allows locking of the CEP frequency below the typically requirements. This integration allows relaxed constraints on the laser systems.The optics and electronics of a high-power, quasi-single cycle laser facility were improved. This thesis included the stabilization of the pump line and the stabilization of the CEP. This work allows for new long-duration experiments.
Show less - Date Issued
- 2013
- Identifier
- CFE0004654, ucf:49908
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004654