View All Items
- Title
- A CUSTOMER PROGRAMMABLE MICROFLUIDIC SYSTEM.
- Creator
-
Liu, Miao, Chen, Quanfang, University of Central Florida
- Abstract / Description
-
Microfluidics is both a science and a technology offering great and perhaps even revolutionary capabilities to impact the society in the future. However, due to the scaling effects there are unknown phenomena and technology barriers about fluidics in microchannel, material properties in microscale and interactions with fluids are still missing. A systematic investigation has been performed aiming to develop "A Customer Programmable Microfluidic System". This innovative Polydimethylsiloxane ...
Show moreMicrofluidics is both a science and a technology offering great and perhaps even revolutionary capabilities to impact the society in the future. However, due to the scaling effects there are unknown phenomena and technology barriers about fluidics in microchannel, material properties in microscale and interactions with fluids are still missing. A systematic investigation has been performed aiming to develop "A Customer Programmable Microfluidic System". This innovative Polydimethylsiloxane (PDMS)-based microfluidic system provides a bio-compatible platform for bio-analysis systems such as Lab-on-a-chip, micro-total-analysis system and biosensors as well as the applications such as micromirrors. The system consists of an array of microfluidic devices and each device containing a multilayer microvalve. The microvalve uses a thermal pneumatic actuation method to switch and/or control the fluid flow in the integrated microchannels. It provides a means to isolate samples of interest and channel them from one location of the system to another based on needs of realizing the customers' desired functions. Along with the fluid flow control properties, the system was developed and tested as an array of micromirrors. An aluminum layer is embedded into the PDMS membrane. The metal was patterned as a network to increase the reflectivity of the membrane, which inherits the deformation of the membrane as a mirror. The deformable mirror is a key element in the adaptive optics. The proposed system utilizes the extraordinary flexibility of PDMS and the addressable control to manipulate the phase of a propagating optical wave front, which in turn can increase the performance of the adaptive optics. Polydimethylsiloxane (PDMS) has been widely used in microfabrication for microfluidic systems. However, few attentions were paid in the past to mechanical properties of PDMS. Importantly there is no report on influences of microfabrication processes which normally involve chemical reactors and biologically reaction processes. A comprehensive study was made in this work to study fundamental issues such as scaling law effects on PDMS properties, chemical emersion and temperature effects on mechanical properties of PDMS, PDMS compositions and resultant properties, as well as bonding strength, etc. Results achieved from this work will provide foundation of future developments of microfluidics utilizing PDMS.
Show less - Date Issued
- 2008
- Identifier
- CFE0002372, ucf:47798
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002372
- Title
- BASIC STUDY OF MICROMACHINED DEP (DIELECTROPHORETIC) MANIPULATOR.
- Creator
-
Sundaram, Vivek, , K.B.Sundaram, University of Central Florida
- Abstract / Description
-
The capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating...
Show moreThe capability of manipulating microparticle in small volumes is fundamental to many biological and medical applications, including separation and detection of cells. The development of microtools for effective sample handling and separation in such volumes is still a challenge. DEP (dielectrophoresis) is one of the most widely used methods in handling the microparticles. In this thesis we show that forces generated by nonuniform electric field (DEP) can be used for trapping and separating the microparticles (latex beads). This work further explores the DEP force based on different electrode geometries and medium conductivity. A micromanipulator for latex bead separation was designed, fabricated and characterized. For the development of DEP manipulator, the fabrication and packaging of microfluidic structure with the microelectrode is crucial for reliable analysis. A combination of SU-8 photoresist and polydimethylsiloxane polymer was used for this purpose. Besides, the DEP manipulator, preliminary study on a Coulter counter was conducted. The Coulter counter works on the principle of resistive pulse sensing. This counter is used for counting the beads as they pass through the microfluidic channel. Its possible integration with the manipulator was also explored.
Show less - Date Issued
- 2004
- Identifier
- CFE0000121, ucf:46178
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0000121
- Title
- PRESSURE LOSSES EXPERIENCED BY LIQUID FLOW THROUGH PDMS MICROCHANNELS WITH ABRUPT AREA CHANGES.
- Creator
-
Wehking, Jonathan, Chew, Larry, University of Central Florida
- Abstract / Description
-
Given the surmounting disagreement amongst researchers in the area of liquid flow behavior at the microscale for the past thirty years, this work presents a fundamental approach to analyzing the pressure losses experienced by the laminar flow of water (Re = 7 to Re = 130) through both rectangular straight duct microchannels (of widths ranging from 50 to 130 micrometers), and microchannels with sudden expansions and contractions (with area ratios ranging from 0.4 to 1.0) all with a constant...
Show moreGiven the surmounting disagreement amongst researchers in the area of liquid flow behavior at the microscale for the past thirty years, this work presents a fundamental approach to analyzing the pressure losses experienced by the laminar flow of water (Re = 7 to Re = 130) through both rectangular straight duct microchannels (of widths ranging from 50 to 130 micrometers), and microchannels with sudden expansions and contractions (with area ratios ranging from 0.4 to 1.0) all with a constant depth of 104 micrometers. The simplified Bernoulli equations for uniform, steady, incompressible, internal duct flow were used to compare flow through these microchannels to macroscale theory predictions for pressure drop. One major advantage of the channel design (and subsequent experimental set-up) was that pressure measurements could be taken locally, directly before and after the test section of interest, instead of globally which requires extensive corrections to the pressure measurements before an accurate result can be obtained. Bernoulli's equation adjusted for major head loses (using Darcy friction factors) and minor head losses (using appropriate K values) was found to predict the flow behavior within the calculated theoretical uncertainty (~12%) for all 150+ microchannels tested, except for sizes that pushed the aspect ratio limits of the manufacturing process capabilities (microchannels fabricated via soft lithography using PDMS). The analysis produced conclusive evidence that liquid flow through microchannels at these relative channel sizes and Reynolds numbers follow macroscale predictions without experiencing any of the reported anomalies expressed in other microfluidics research. This work also perfected the delicate technique required to pierce through the PDMS material and into the microchannel inlets, exit and pressure ports without damaging the microchannel. Finally, two verified explanations for why prior researchers have obtained poor agreement between macroscale theory predictions and tests at the microscale were due to the presence of bubbles in the microchannel test section (producing higher than expected pressure drops), and the occurrence of localized separation between the PDMS slabs and thus, the microchannel itself (producing lower than expected pressure drops).
Show less - Date Issued
- 2008
- Identifier
- CFE0002289, ucf:47865
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002289
- Title
- Development of in vitro point of care diagnostics (IVPCD) based on Aptamers integrated Biosensors.(&)nbsp;.
- Creator
-
Saraf, Nileshi, Seal, Sudipta, Fang, Jiyu, Florczyk, Stephen, Dong, Yajie, Self, William, University of Central Florida
- Abstract / Description
-
The global market for the medical diagnostic industry is worth 25 billion dollars in the United States and is expected to grow exponentially each year. Presently available methods for biodetection, such as immunoassays, chemiluminescence and fluorescent based assays are expensive, time consuming and require skilled labor with high-end instruments. Therefore, development of novel, passive colorimetric sensors and diagnostic technologies for detection and surveillance is of utmost importance...
Show moreThe global market for the medical diagnostic industry is worth 25 billion dollars in the United States and is expected to grow exponentially each year. Presently available methods for biodetection, such as immunoassays, chemiluminescence and fluorescent based assays are expensive, time consuming and require skilled labor with high-end instruments. Therefore, development of novel, passive colorimetric sensors and diagnostic technologies for detection and surveillance is of utmost importance especially in resource constrained communities. The present work focusses on developing novel and advanced in vitro biodiagnostic tools based on aptamer integrated biosensors for an early detection of specific viral proteins or small biomolecules used as potential markers for deadly diseases. Aptamers are short single stranded deoxyribonucleic acid (DNA) which are designed to bind to a specific target biomolecule. These are readily synthesized in laboratory and offers several advantages over antibodies/enzymes such as stable in harsh environment, easily functionalized for immobilization, reproducibility etc. These undergo conformational changes upon target binding and produces physical or chemical changes in the system which are measured as colorimetric or electrochemical signals. Here, we have explored the aptamer-analyte interaction on different platforms such as microfluidic channel, paper based substrate as well as organic electrochemical transistor to develop multiple compact, robust and self-contained diagnostic tools. These testing tools exhibit high sensitivity (detection limit in picomolar) and selectivity against the target molecule, require no sophisticated instruments or skilled labor to implement and execute, leading a way to cheaper and more consumer driver health care. These innovative platforms provide flexibility to incorporate additional or alternative targets by simply designing aptamers to bind to the specific biomolecule.
Show less - Date Issued
- 2018
- Identifier
- CFE0007766, ucf:52388
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0007766