Wilder, Rebecca, Duranceau, Steven, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
The research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced...
Show moreThe research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced DBP formation potential, integration of the NF process altered finished water quality parameters including pH, alkalinity and hardness. There was concern that these changes could result in secondary impacts related to accelerated corrosion of distribution system components and subsequent regulatory compliance. In addition, replacement of the LS process altered the in-plant blending operations by creating an unstable intermediate blend composed of RO and IX waters. There were concerns that this intermediate blend was affecting the integrity of in-plant hydraulic conveyance components.UCF developed a corrosion monitoring study to assess the potential impacts related to internal corrosion, water quality and regulatory compliance after integrating NF into the existing water supply. The intended purpose was to further highlight the complexities of corrosion, describe a unique approach to corrosion monitoring as well as offer various recommendations for corrosion control in a system that relies on a blended water supply. Research was conducted in three phases to address the in-plant and distribution system corrosion issues separately and identify appropriate corrosion control treatment alternatives. The three test phases included: a baseline conditions assessment to compare corrosion of the intermediate RO-IX blend with the finished water blend (RO-IX-NF); an in-plant corrosion control evaluation; and a distribution system corrosion control evaluation.A test apparatus was constructed and operated at the Town's facilities to monitor corrosion activity of mild steel, copper and lead solder metal components. The test apparatus consisted of looped PVC pipe segments housed with electrochemical probes and metal coupons to monitor corrosion rates of the metallic components. Electrochemical probes containing metal electrodes were used to obtain instantaneous corrosion rates by means of the Linear Polarization Resistance (LPR) technique while the metal coupons were gravimetrically evaluated for weight loss. The electrochemical probes permitted daily monitoring of each metal's corrosion rates while metal coupons were analyzed at the conclusion of testing and used for comparison. Different test waters flowed through the corrosion rack according to each test phase and relative corrosion rates were compared to evaluate corrosion control techniques.Study findings indicated that the intermediate blend was more corrosive, in general, then the final blend; however, research also indicated that the final blend of water was increasing lead and copper concentrations within the distribution system. An orthophosphate corrosion inhibitor was evaluated for in-plant corrosion control. The inhibitor's performance was assessed by comparing mild steel corrosion rates with and without the chemical. In addition, secondary impacts related to introduction of the chemical were evaluated by pre-corroding the metallic components prior to the introduction of the inhibitor. Results indicated that the inhibitor marginally decreased corrosion rates and increased the turbidity of the water supply. Based on these observations, it was concluded that the inhibitor was not a viable solution for in-plant corrosion control. To resolve in-plant corrosion issues, recommendations were made for modification of in-plant blending operations to eliminate the corrosive intermediate blend from the process allowing the RO, IX and NF treated waters to be blended in a common location. The effectiveness of a poly/ortho blended phosphate chemical inhibitor was evaluated for reducing lead and copper corrosion to resolve distribution corrosion issues. A 50/50 poly/ortho blend was selected because of its analogous use in similar municipal water facilities. Metallic corrosion rates, particularly lead and copper, were compared with and without the inhibitor to assess the performance of the chemical. Like the previous test phase, the metallic components were pre-corroded prior to the chemical's introduction to determine if secondary impacts could result from its presence. Results indicated that lead and copper corrosion rates were lower in the presence of the inhibitor, and secondary impacts related to increased turbidity were not observed for this chemical. Based on these results, it was recommended that a poly/ortho blended phosphate be used to decrease lead and copper corrosion within the Town's distribution system.
Show less - Date Issued
- 2012
- Identifier
- CFE0004460, ucf:49349
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004460
- Title
- BIOSTABILITY IN DRINKING WATER DISTRIBUTION SYSTEMS IN A CHANGING WATER QUALITY ENVIRONMENT USING CORROSION INHIBITORS.
- Creator
-
Zhao, Bingjie, Randall, Andrew, University of Central Florida
- Abstract / Description
-
In this study, the bacterial growth dynamics of 14 pilot drinking water distribution systems were studied in order to observe water quality changes due to corrosion inhibitor addition. Empirical models were developed to quantity the effect of inhibitor type and dose on bacterial growth (biofilm and bulk water). Water and pipe coupon samples were taken and examined during the experiments. The coupons were exposed to drinking water at approximately 20 °C for at least 5 weeks to allow the...
Show moreIn this study, the bacterial growth dynamics of 14 pilot drinking water distribution systems were studied in order to observe water quality changes due to corrosion inhibitor addition. Empirical models were developed to quantity the effect of inhibitor type and dose on bacterial growth (biofilm and bulk water). Water and pipe coupon samples were taken and examined during the experiments. The coupons were exposed to drinking water at approximately 20 °C for at least 5 weeks to allow the formation of a measurable quasi- steady-state biofilm. Bulk water samples were taken every week. In this study, two simple but practical empirical models were created. Sensitivity analysis for the bulk HPC model (for all 14 of the PDSs) showed that maintaining a chloramine residual at 2.6 mg/L instead of 1.1 mg/L would decrease bulk HPC by anywhere from 0.5 to 0.9 log, which was greater than the increase in bulk HPC from inhibitor addition at 0.31 to 0.42 log for Si and P based inhibitors respectively. This means that maintaining higher residual levels can counteract the relatively modest increases due to inhibitors. BF HPC was affected by pipe material, effluent residual and temperature in addition to a small increase due to inhibitor addition. Biofilm density was most affected by material type, with polyvinyl chloride (PVC) biofilm density consistently much lower than other materials (0.66, 0.92, and 1.22 log lower than lined cast iron (LCI), unlined cast iron (UCI), and galvanized steel (G), respectively). Temperature had a significant effect on both biofilm and bulk HPC levels but it is not practical to alter temperature for public drinking water distribution systems so temperature is not a management tool like residual. This study evaluated the effects of four different corrosion inhibitors (i.e. based on either phosphate or silica) on drinking water distribution system biofilms and bulk water HPC levels. Four different pipe materials were used in the pilot scale experiments, polyvinyl chloride (PVC), lined cast iron (LCI), unlined cast iron (UCI), and galvanized steel (G). Three kinds of phosphate based and one silica based corrosion inhibitors were added at concentrations typically applied in a drinking water distribution system for corrosion control. The data showed that there was a statistically significant increase of 0.34 log in biofilm bacterial densities (measured as HPC) with the addition of any of the phosphate based inhibitors (ortho-phosphorus, blended ortho-poly-phosphate, and zinc ortho-phosphate). A silica based inhibitor resulted in an increase of 0.36 log. The biological data also showed that there was a statistically significant increase in bulk water bacterial densities (measured as heterotrophic plates count, HPC) with the addition of any of the four inhibitors. For bulk HPC this increase was relatively small, being 15.4% (0.42 log) when using phosphate based inhibitors, and 11.0% (0.31 log) for the silica based inhibitor. Experiments with PDS influent spiked with phosphate salts, phosphate based inhibitors, and the silicate inhibitor showed that the growth response of P17 and NOx in the AOC test was increased by addition of these inorganic compounds. For this source water and the PDSs there was more than one limiting nutrient. In addition to organic compounds phosphorus was identified as a nutrient stimulating growth, and there was also an unidentified nutrient in the silica based inhibitor. However since the percentage increases due to inhibitors were no greater than 15% it is unlikely that this change would be significant for the bulk water microbial quality. In addition it was shown that increasing the chloramines residual could offset any additional growth and that the inhibitors could help compliance with the lead and copper rule. However corrosion inhibitors might result in an increase in monitoring and maintenance requirements, particularly in dead ends, reaches with long HRTs, and possibly storage facilities. In addition it is unknown what the effect of corrosion inhibitors are on the growth of coliform bacteria and opportunistic pathogens relative to ordinary heterotrophs. A method was developed to monitor precision for heterotrophic plate count (HPC) using both blind duplicates and lab replicates as part of a project looking at pilot drinking water distribution systems. Precision control charts were used to monitor for changes in assay variability with time just as they are used for chemical assays. In adapting these control charts for the HPC assay, it was determined that only plate counts ≥ 30 cfu per plate could be used for Quality Assurance (QA) purposes. In addition, four dilutions were used for all known Quality Control (QC) samples to insure counts usable for QC purposes would be obtained. As a result there was a 50% increase in the required labor for a given number of samples when blind duplicates and lab replicates were run in parallel with the samples. For bulk water HPCs the distributions of the duplicate and replicate data were found to be significantly different and separate control charts were used. A probability based analysis for setting up the warning limit (WL) and control limit (CL) was compared with the method following National Institute of Standard and Technology (NIST) guidelines.
Show less - Date Issued
- 2007
- Identifier
- CFE0001947, ucf:47452
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0001947
- Title
- IMPACT OF ZINC ORTHOPHOSPHATE INHIBITOR ONDISTRIBUTION SYSTEM WATER QUALITY.
- Creator
-
Guan, Xiaotao, Taylor, James, University of Central Florida
- Abstract / Description
-
This dissertation consists of four papers concerning impacts of zinc orthophosphate (ZOP) inhibitor on iron, copper and lead release in a changing water quality environment. The mechanism of zinc orthophosphate corrosion inhibition in drinking water municipal and home distribution systems and the role of zinc were investigated. Fourteen pilot distribution systems (PDSs) which were identical and consisted of increments of PVC, lined cast iron, unlined cast iron and galvanized steel pipes were...
Show moreThis dissertation consists of four papers concerning impacts of zinc orthophosphate (ZOP) inhibitor on iron, copper and lead release in a changing water quality environment. The mechanism of zinc orthophosphate corrosion inhibition in drinking water municipal and home distribution systems and the role of zinc were investigated. Fourteen pilot distribution systems (PDSs) which were identical and consisted of increments of PVC, lined cast iron, unlined cast iron and galvanized steel pipes were used in this study. Changing quarterly blends of finished ground, surface and desalinated waters were fed into the pilot distribution systems over a one year period. Zinc orthophosphate inhibitor at three different doses was applied to three PDSs. Water quality and iron, copper and lead scale formation was monitored for the one year study duration. The first article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on surface characteristics of iron corrosion products in a changing water quality environment. Surface compositions of iron surface scales for iron and galvanized steel coupons incubated in different blended waters in the presence of ZOP inhibitor were investigated using X-ray Photoelectron Spectroscopy (XPS), Scanning Electron Microscopy (SEM) / Energy Dispersive X-ray Spectroscopy (EDS). Based on surface characterization, predictive equilibrium models were developed to describe the controlling solid phase and mechanism of ZOP inhibition and the role of zinc for iron release. The second article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total iron release in a changing water quality environment. Development of empirical models as a function of water quality and ZOP inhibitor dose for total iron release and mass balances analysis for total zinc and total phosphorus data provided insight into the mechanism of ZOP corrosion inhibition regarding iron release in drinking water distribution systems. The third article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total copper release in a changing water quality environment. Empirical model development was undertaken for prediction of total copper release as a function of water quality and inhibitor dose. Thermodynamic models for dissolved copper based on surface characterization of scale that were generated on copper coupons exposed to ZOP inhibitor were also developed. Surface composition was determined by X-ray Photoelectron Spectroscopy (XPS). The fourth article describes the effects of zinc orthophosphate (ZOP) corrosion inhibitor on total lead release in a changing water quality environment. Surface characterization of lead scale on coupons exposed to ZOP inhibitor by X-ray Photoelectron Spectroscopy (XPS) was utilized to identify scale composition. Development of thermodynamic model for lead release based on surface analysis results provided insight into the mechanism of ZOP inhibition and the role of zinc.
Show less - Date Issued
- 2007
- Identifier
- CFE0001931, ucf:47453
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0001931
- Title
- Control of Metal-Release and Tuberculation in a Silica-Laden Groundwater Distribution System on the Volcanic Island of Lana'i.
- Creator
-
Myers, Samantha, Duranceau, Steven, Sadmani, A H M Anwar, Lee, Woo Hyoung, University of Central Florida
- Abstract / Description
-
A corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several...
Show moreA corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several groundwater wells feed each of the WDS's; however, water quality between wells varies. Well water supplied to the WDS's is generally of high quality, therefore, the historical treatment method has been limited to disinfection prior to distribution. The distribution system consists of several materials of construction, which includes galvanized iron. Valves and pipes within the WDS were experiencing visible corrosion and tuberculation believed to be responsible for variable pressure drop throughout portions of the system.In this work, two corrosion racks, each consisting of two parallel loops, were designed, constructed, and installed at each site. One loop was maintained as a control while the other loop was used for testing alternative corrosion inhibitors. The racks utilized metal sample coupons and linear polarization resistance probes to provide data on corrosion rates of selected metals of interest.Results indicated that the water in Manele Bay experienced no noticeable change between the test loop and control loop when a corrosion inhibitor was added. A first experiment found the corrosion rates reached baseline steady(-)state at 4,000 operational hours. A second experiment found that the corrosion rates reached baseline steady(-)state at 2,200 operational hours. During these two experiments, the addition of a phosphate or silica(-)based inhibitor neither reduced nor increased the corrosion rates of mild steel, lead, and copper.Results from Lana'i City indicated that inhibitors offered little to no positive effect between the control condition and the test condition. During the first experiment, baseline corrosion was reached after 2,400 hours. The addition of a phosphate inhibitor did not reduce nor increase the corrosion rates of mild steel and lead. However, the corrosion rate of copper increased to 1.0mpy from 0.22mpy. The corrosion rate remained elevated after inhibitor feed was terminated. The second experiment reached baseline corrosion rates at 1,400 operational hours. The use of silica inhibitor neither reduced nor increased the corrosion rate of mil steel, lead, and copper.Since corrosion inhibitors were found to be ineffective, a valve exercise and replacement program for Pulama's assets was recommended. This program included: (1) developing a detailed asset inventory, (2) implementing operation and maintenance tasks, (3) forming a valve replacement plan, and (4) establishing long range financial planning. An opinion of probable replacement cost for 200 new valves was conceptually estimated to approximate 3.3 million dollars expended over a 20 year time frame.
Show less - Date Issued
- 2016
- Identifier
- CFE0006152, ucf:51152
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0006152
- Title
- In-Plant and Distribution System Corrosion Control for Reverse Osmosis, Nanofiltration, and Anion Exchange Process Blends.
- Creator
-
Jeffery, Samantha, Duranceau, Steven, Randall, Andrew, Wang, Dingbao, University of Central Florida
- Abstract / Description
-
The integration of advanced technologies into existing water treatment facilities (WTFs) can improve and enhance water quality; however, these same modifications or improvements may adversely affect finished water provided to the consumer by public water systems (PWSs) that embrace these advanced technologies. Process modification or improvements may unintentionally impact compliance with the provisions of the United States Environmental Protection Agency's (USEPA's) Safe Drinking Water Act ...
Show moreThe integration of advanced technologies into existing water treatment facilities (WTFs) can improve and enhance water quality; however, these same modifications or improvements may adversely affect finished water provided to the consumer by public water systems (PWSs) that embrace these advanced technologies. Process modification or improvements may unintentionally impact compliance with the provisions of the United States Environmental Protection Agency's (USEPA's) Safe Drinking Water Act (SDWA). This is especially true with respect to corrosion control, since minor changes in water quality can affect metal release. Changes in metal release can have a direct impact on a water purveyor's compliance with the SDWA's Lead and Copper Rule (LCR). In 2010, the Town of Jupiter (Town) decommissioned its ageing lime softening (LS) plant and integrated a nanofiltration (NF) plant into their WTF. The removal of the LS process subsequently decreased the pH in the existing reverse osmosis (RO) clearwell, leaving only RO permeate and anion exchange (AX) effluent to blend. The Town believed that the RO-AX blend was corrosive in nature and that blending with NF permeate would alleviate their concern. Consequently, a portion of the NF permeate stream was to be split between the existing RO-AX clearwell and a newly constructed NF primary clearwell. The Town requested that the University of Central Florida (UCF) conduct research evaluating how to mitigate negative impacts that may result from changing water quality, should the Town place its AX into ready-reserve. The research presented in this document was focused on the evaluation of corrosion control alternatives for the Town, and was segmented into two major components: 1.The first component of the research studied internal corrosion within the existing RO clearwell and appurtenances of the Town's WTF, should the Town place the AX process on standby. Research related to WTF in-plant corrosion control focused on blending NF and RO permeate, forming a new intermediate blend, and pH-adjusting the resulting mixture to reduce corrosion in the RO clearwell. 2.The second component was implemented with respect to the Town's potable water distribution system. The distribution system corrosion control research evaluated various phosphate-based corrosion inhibitors to determine their effectiveness in reducing mild steel, lead and copper release in order to maintain the Town's continual compliance with the LCR.The primary objective of the in-plant corrosion control research was to determine the appropriate ratio of RO to NF permeate and the pH necessary to reduce corrosion in the RO clearwell. In this research, the Langelier saturation index (LSI) was the corrosion index used to evaluate the stability of RO:NF blends. Results indicated that a pH-adjusted blend consisting of 70% RO and 30% NF permeate at 8.8-8.9 pH units would produce an LSI of +0.1, theoretically protecting the RO clearwell from corrosion.The primary objective of the distribution system corrosion control component of the research was to identify a corrosion control inhibitor that would further reduce lead and copper metal release observed in the Town's distribution system to below their respective action limits (ALs) as defined in the LCR. Six alternative inhibitors composed of various orthophosphate and polyphosphate (ortho:poly) ratios were evaluated sequentially using a corrosion control test apparatus. The apparatus was designed to house mild steel, lead and copper coupons used for weight loss analysis, as well as mild steel, lead solder and copper electrodes used for linear polarization analysis. One side of the apparatus, referred to as the (")control condition,(") was fed potable water that did not contain the corrosion inhibitor, while the other side of the corrosion apparatus, termed the (")test condition,(") was fed potable water that had been dosed with a corrosion inhibitor. Corrosion rate measurements were taken twice per weekday, and water quality was measured twice per week. Inhibitor evaluations were conducted over a span of 55 to 56 days, varying with each inhibitor. Coupons and electrodes were pre-corroded to simulate existing distribution system conditions. Water flow to the apparatus was controlled with an on/off timer to represent variations in the system and homes. Inhibitor comparisons were made based on their effectiveness at reducing lead and copper release after chemical addition. Based on the results obtained from the assessment of corrosion inhibitors for distribution system corrosion control, it appears that Inhibitors 1 and 3 were more successful in reducing lead corrosion rates, and each of these inhibitors reduced copper corrosion rates. Also, it is recommended that consideration be given to use of a redundant single-loop duplicate test apparatus in lieu of a double rack corrosion control test apparatus in experiments where pre-corrosion phases are implemented. This recommendation is offered because statistically, the control versus test double loop may not provide relevance in data analysis. The use of the Wilcoxon signed ranks test comparing the initial pre-corroding phase to the inhibitor effectiveness phase has proven to be a more useful analytical method for corrosion studies.
Show less - Date Issued
- 2013
- Identifier
- CFE0005008, ucf:50001
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0005008
- Title
- THE EFFECTS OF PHOSPHATE AND SILICATE INHIBITORS ON SURFACE ROUGHNESS AND COPPER RELEASE IN WATER DISTRIBUTION SYSTEMS.
- Creator
-
MacNevin, David, Taylor, James, University of Central Florida
- Abstract / Description
-
The effects of corrosion inhibitors on water quality and the distribution system were studied. This dissertation investigates the effect of inhibitors on iron surface roughness, copper surface roughness, and copper release. Corrosion inhibitors included blended poly/ortho phosphate, sodium orthophosphate, zinc orthophosphate, and sodium silicate. These inhibitors were added to a blend of surface water, groundwater, and desalinated brackish water. Surface roughness of galvanized iron, unlined...
Show moreThe effects of corrosion inhibitors on water quality and the distribution system were studied. This dissertation investigates the effect of inhibitors on iron surface roughness, copper surface roughness, and copper release. Corrosion inhibitors included blended poly/ortho phosphate, sodium orthophosphate, zinc orthophosphate, and sodium silicate. These inhibitors were added to a blend of surface water, groundwater, and desalinated brackish water. Surface roughness of galvanized iron, unlined cast iron, lined cast iron, and polyvinyl chloride was measured using pipe coupons exposed for three months. Roughness of each pipe coupon was measured with an optical surface profiler before and after exposure to inhibitors. For most materials, inhibitor did not have a significant effect on surface roughness; instead, the most significant factor determining the final surface roughness was the initial surface roughness. Coupons with low initial surface roughness tended to have an increase in surface roughness during exposure, and vice versa, implying that surface roughness tended to regress towards an average or equilibrium value. For unlined cast iron, increased alkalinity and increased temperature tended to correspond with increases in surface roughness. Unlined cast iron coupons receiving phosphate inhibitors were more likely to have a significant change in surface roughness, suggesting that phosphate inhibitors affect stability of iron pipe scales. Similar roughness data collected with new copper coupons showed that elevated orthophosphate, alkalinity, and temperature were all factors associated with increased copper surface roughness. The greatest increases in surface roughness were observed with copper coupons receiving phosphate inhibitors. Smaller increases were observed with copper coupons receiving silicate inhibitor or no inhibitor. With phosphate inhibitors, elevated temperature and alkalinity were associated with larger increases in surface roughness and blue-green copper (II) scales.. Otherwise a compact, dull red copper (I) scale was observed. These data suggest that phosphate inhibitor addition corresponds with changes in surface morphology, and surface composition, including the oxidation state of copper solids. The effects of corrosion inhibitors on copper surface chemistry and cuprosolvency were investigated. Most copper scales had X-ray photoelectron spectroscopy binding energies consistent with a mixture of Cu2O, CuO, Cu(OH)2, and other copper (II) salts. Orthophosphate and silica were detected on copper surfaces exposed to each inhibitor. All phosphate and silicate inhibitors reduced copper release relative to the no inhibitor treatments, keeping total copper below the 1.3 mg/L MCLG for all water quality blends. All three kinds of phosphate inhibitors, when added at 1 mg/L as P, corresponded with a 60% reduction in copper release relative to the no inhibitor control. On average, this percent reduction was consistent across varying water quality conditions in all four phases. Similarly when silicate inhibitor was added at 6 mg/L as SiO2, this corresponded with a 25-40% reduction in copper release relative to the no inhibitor control. Hence, on average, for the given inhibitors and doses, phosphate inhibitors provided more predictable control of copper release across changing water quality conditions. A plot of cupric ion concentration versus orthophosphate concentration showed a decrease in copper release consistent with mechanistic control by either cupric phosphate solubility or a diffusion limiting phosphate film. Thermodynamic models were developed to identify feasible controlling solids. For the no inhibitor treatment, Cu(OH)2 provided the closest prediction of copper release. With phosphate inhibitors both Cu(OH)2 and Cu(PO4)·2H2O models provided plausible predictions. Similarly, with silicate inhibitor, the Cu(OH)2 and CuSiO3·H2O models provided plausible predictions.
Show less - Date Issued
- 2008
- Identifier
- CFE0002001, ucf:47621
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002001
- Title
- EFFECTS OF SOURCE WATER BLENDING FOLLOWING TREATMENT WITH SODIUM SILICATE AS A CORROSION INHIBITOR ON METAL RELEASE WITHIN A WATER DISTRIBUTION SYSTEM.
- Creator
-
Lintereur, Phillip, Duranceau, Steven, University of Central Florida
- Abstract / Description
-
A study was conducted to investigate and quantify the effects of corrosion inhibitors on metal release within a pilot distribution system while varying the source water. The pilot distribution system consisted of pre-existing facilities from Taylor et al (2005). Iron, copper, and lead release data were collected during four separate phases of operation. Each phase was characterized by the particular blend ratios used during the study. A blended source water represented a water that had been...
Show moreA study was conducted to investigate and quantify the effects of corrosion inhibitors on metal release within a pilot distribution system while varying the source water. The pilot distribution system consisted of pre-existing facilities from Taylor et al (2005). Iron, copper, and lead release data were collected during four separate phases of operation. Each phase was characterized by the particular blend ratios used during the study. A blended source water represented a water that had been derived from a consistent proportion of three different source waters. These source waters included (1) surface water treated through enhanced coagulation/sedimentation/filtration, (2) conventionally treated groundwater, and (3) finished surface water treated using reverse osmosis membranes. The corrosion inhibitors used during the study were blended orthophosphate (BOP), orthophosphate (OP), zinc orthophosphate (ZOP), and sodium silicate (Si). This document was intended to cite the findings from the study associated with corrosion treatment using various doses of sodium silicate. The doses were maintained to 3, 6, and 12 mg/L as SiO2 above the blend-dependent background silica concentration. Sources of iron release within the pilot distribution system consisted of, in the following order of entry, (1) lined cast iron, (2) un-lined cast iron, and (3) galvanized steel. Iron release data from these materials was not collected for each individual iron source. Instead, iron release data represented the measurement of iron upon exposure to the pilot distribution system in general. There was little evidence to suggest that iron release was affected by sodium silicate. Statistical modeling of iron release suggested that iron release could be described by the water quality parameters of alkalinity, chlorides, and pH. The R2 statistic implied that the model could account for only 36% of the total variation within the iron release data set (i.e. R2 = 0.36). The model implies that increases in alkalinity and pH would be expected to decrease iron release on average, while an increase in chlorides would increase iron release. The surface composition of cast iron and galvanized steel coupons were analyzed using X-ray photoelectron spectroscopy (XPS). The surface analysis located binding energies consistent with Fe2O3, Fe3O4, and FeOOH for both cast iron and galvanized steel. Elemental scans detected the presence of silicon as amorphous silica; however, there was no significant difference between scans of coupons treated with sodium silicate and coupons simply exposed to the blended source water. The predominant form of zinc found on the galvanized steel coupons was ZnO. Thermodynamic modeling of the galvanized steel system suggested that zinc release was more appropriately described by Zn5(CO3)2(OH)6. The analysis of the copper release data set suggested that treatment with sodium silicate decreased copper release during the study. On average the low, medium, and high doses decreased copper release, when compared to the original blend source water prior to sodium silicate addition, by approximately 20%, 30%, and 50%, respectively. Statistical modeling found that alkalinity, chlorides, pH, and sodium silicate dose were significant variables (R2 = 0.68). The coefficients of the model implied that increases in pH and sodium silicate dose decreased copper release, while increases in alkalinity and chlorides increased copper release. XPS for copper coupons suggested that the scale composition consisted of Cu2O, CuO, and Cu(OH)2 for both the coupons treated with sodium silicate and those exposed to the blended source water. Analysis of the silicon elemental scan detected amorphous silica on 3/5 copper coupons exposed to sodium silicate. Silicon was not detected on any of the 8 control coupons. This suggested that sodium silicate inhibitor varied the surface composition of the copper scale. The XPS results seemed to be validated by the visual differences of the copper coupons exposed to sodium silicate. Copper coupons treated with sodium silicate developed a blue-green scale, while control coupons were reddish-brown. Thermodynamic modeling was unsuccessful in identifying a controlling solid that consisted of a silicate-based cupric solid. Lead release was generally decreased when treated with sodium silicate. Many of the observations were recorded below the detection limit (1 ppb as Pb) of the instrument used to measure the lead concentration of the samples during the study. The frequency of observations below the detection limit tended to increase as the dose of sodium silicate increased. An accurate quantification of the effect of sodium silicate was complicated by the observations recorded below detection limit. If the lead concentration of a sample was below detection limit, then the observation was recorded as 1 ppb. Statistical modeling suggested that temperature, alkalinity, chlorides, pH, and sodium silicate dose were important variables associated with lead release (R2 = 0.60). The exponents of the non-linear model implied that an increase in temperature, alkalinity, and chlorides increased lead release, while an increase in pH and sodium silicate dose were associated with a decrease in lead release. XPS surface characterization of lead coupons indicated the presence of PbO, PbO2, PbCO3, and Pb3(OH)2(CO3)2. XPS also found evidence of silicate scale formation. Thermodynamic modeling did not support the possibility of a silicate-based lead controlling solid. A solubility model assuming Pb3(OH)2(CO3)2 as the controlling solid was used to evaluate lead release data from samples in which lead coupons were incubated for long stagnation times. This thermodynamic model seemed to similarly describe the lead release of samples treated with sodium silicate and samples exposed to the blended source water. The pH of each sample was similar, thus sodium silicate, rather than the corresponding increase in pH, would appear to be responsible if a difference had been observed. During the overall study, the effects of BOP, OP, ZOP, and Si corrosion inhibitors were described by empirical models. Statistically, the model represented the expected value, or mean average, function. If these models are to be used to predict a dose for copper release, then the relationship between the expected value function and the 90th percentile must be approximated. The USEPA Lead and Copper Rule (LCR) regulates total copper release at an action level of 1.3 mg/L. This action level represents a 90th percentile rather than a mean average. Evaluation of the complete copper release data set suggested that the standard deviation was proportional to the mean average of a particular treatment. This relationship was estimated using a linear model. It was found that most of the copper data sub-sets (represented by a given phase, inhibitor, and dose) could be described by a normal distribution. The information obtained from the standard deviation analysis and the normality assumption validated the use of a z-score to relate the empirical models to the estimated 90th percentile observations. Since an analysis of the normality and variance (essentially contains the same information as the standard deviation) are required to assess the assumptions associated with an ANOVA, an ANOVA was performed to directly compare the effects of the inhibitors and corresponding doses. The findings suggested that phosphate-based inhibitors were consistently more effective than sodium silicate when comparing the same treatment levels (i.e. doses). Among the phosphate-based inhibitors, the effectiveness of each respective treatment level was inconsistent (i.e. there was no clear indication that any one phosphate-based inhibitor was more effective than the other). As the doses increased for each inhibitor, the results generally suggested that there was a corresponding tendency for copper release to decrease.
Show less - Date Issued
- 2008
- Identifier
- CFE0002383, ucf:47737
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002383
- Title
- IMPACT OF CORROSION INHIBITOR BLENDED ORTHOPHOSPHATE ON WATER QUALITY IN WATER DISTRIBUTION SYSTEMS.
- Creator
-
Alshehri, Abdulrahman, Taylor, James, University of Central Florida
- Abstract / Description
-
The impact of blended orthophosphate (BOP) inhibitor addition on the corrosion of iron, copper, and lead in drinking water distribution systems was studied under changing water quality environment. Release of iron, copper, and lead were monitored at varying inhibitor doses and changing blends of source waters (groundwater, surface water, and desalinated water). Solid corrosion products on pipe surfaces under BOP treatment were evaluated with surface characterization techniques. Performance of...
Show moreThe impact of blended orthophosphate (BOP) inhibitor addition on the corrosion of iron, copper, and lead in drinking water distribution systems was studied under changing water quality environment. Release of iron, copper, and lead were monitored at varying inhibitor doses and changing blends of source waters (groundwater, surface water, and desalinated water). Solid corrosion products on pipe surfaces under BOP treatment were evaluated with surface characterization techniques. Performance of the BOP inhibitor was compared to other corrosion control strategies. Iron scales for iron and galvanized steel coupons incubated in different blended waters in the presence of BOP inhibitor were analyzed by X-ray Photoelectron Spectroscopy (XPS) for surface composition. Identified iron corrosion products were ferric oxide (Fe2O3), magnetite (Fe3O4), and hydrated ferric oxide (FeOOH), in addition to ferric phosphate (FePO4) on coupons exposed to BOP inhibitor. Variations of water quality did not significantly affect the distribution of solid iron forms on surface films. Thermodynamic modeling indicated siderite (FeCO3) was the controlling solid phase of iron release. XPS indicated addition of BOP inhibitor produced a solid phosphate film in the iron scale which could inhibit iron release. Impact of BOP, orthophosphate, and pH adjustment on iron release in a distribution system was examined. Iron release was sensitive to water quality variations (alkalinity and chloride) associated with source and blends of finished water. Finished waters with high alkalinity content (between 149 and 164 mg/L as CaCO3) consistently mitigated iron release regardless of inhibitor use. Dissolved iron constituted about 10% of total iron release. Empirical models were developed that related water quality, inhibitor type and dose to iron release. The BOP inhibitor minimized total iron release followed closely by increasing pH (between 7.9 and 8.1), while orthophosphate dose did not affect iron release. Temperature (ranged from 21.2 to 25.3) had limited influence on iron release with BOP treatment. Monitoring copper release showed that dissolved copper was the dominant form in the effluent, at about 88%. BOP inhibitor doses of 0.5 to 2.0 mg/L proved beneficial in controlling copper concentrations to an average of below 0.5 mg/L. Control of copper release improved with increasing BOP dose, despite changes in alkalinity. Elevation of pH by 0.3 unit beyond pHs (between 7.9 and 8.1) resulted in noticeable decrease in copper concentrations of about 30%, but was more sensitive to higher alkalinity (146 to 151 mg/L as CaCO3) than BOP treatment. Developed empirical models confirmed the importance of BOP inhibitor dose, pH increase, and alkalinity content on copper release. Statistical comparison of the corrosion control strategies proved the advantage of BOP inhibitor, at all doses, over pH elevation in controlling copper release. The BOP inhibitor mitigated lead release below action level, and consistently outperformed pH elevation, in all water quality conditions. XPS analysis identified lead dioxide (PbO2), lead oxide (PbO), cerussite (PbCO3), and hydrocerussite (Pb3(CO3)2(OH)2) as the corrosion products in the scale of lead/tin coupons exposed to BOP inhibitor. XPS and Scanning Electron Microscopy (SEM) analysis suggested cerussite or hydrocerussite is the controlling solid phase of lead release. Thermodynamic models for cerussite and hydrocerussite grossly over predicted actual concentrations. Solubility and equilibrium relationships suggested the possibility of a lead orthophosphate solid that would describe the effectiveness of BOP inhibitor, although no lead-phosphate solid was detected by surface analysis. BOP inhibitor appeared to have mitigated lead release by forming a surface film between lead scale and the bulk water.
Show less - Date Issued
- 2008
- Identifier
- CFE0002229, ucf:47922
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002229
- Title
- EFFECTS OF ORTHOPHOSPHATE CORROSION INHIBITOR IN BLENDED WATER QUALITY ENVIRONMENTS.
- Creator
-
Stone, Erica, Duranceau, Steven, University of Central Florida
- Abstract / Description
-
This study evaluated the effects of orthophosphate (OP) inhibitor addition on iron, copper, and lead corrosion on coupons exposed to different blends of groundwater, surface water, and desalinated seawater. The effectiveness of OP inhibitor addition on iron, copper, and lead release was analyzed by statistical comparison between OP treated and untreated pilot distribution systems (PDS). Four different doses of OP inhibitor, ranging from zero (control) to 2 mg/L as P, were investigated and non...
Show moreThis study evaluated the effects of orthophosphate (OP) inhibitor addition on iron, copper, and lead corrosion on coupons exposed to different blends of groundwater, surface water, and desalinated seawater. The effectiveness of OP inhibitor addition on iron, copper, and lead release was analyzed by statistical comparison between OP treated and untreated pilot distribution systems (PDS). Four different doses of OP inhibitor, ranging from zero (control) to 2 mg/L as P, were investigated and non-linear empirical models were developed to predict iron, copper, and lead release from the water quality and OP doses. Surface characterization evaluations were conducted using X-ray Photoelectron Spectroscopy (XPS) analyses for each iron, galvanized steel, copper, and lead/tin coupon tested. Also, a theoretical thermodynamic model was developed and used to validate the controlling solid phases determined by XPS. A comparison of the effects of phosphate-based corrosion inhibitor addition on iron, copper, and lead release from the PDSs exposed to the different blends was also conducted. Three phosphate-based corrosion inhibitors were employed; blended orthophosphate (BOP), orthophosphate (OP), and zinc orthophosphate (ZOP). Non-linear empirical models were developed to predict iron, copper, and lead release from each PDS treated with different doses of inhibitor ranging from zero (control) to 2 mg/L as P. The predictive models were developed using water quality parameters as well as the inhibitor dose. Using these empirical models, simulation of the water quality of different blends with varying alkalinity and pH were used to compare the inhibitors performance for remaining in compliance for iron, copper and lead release. OP inhibitor addition was found to offer limited improvement of iron release for the OP dosages evaluated for the water blends evaluated compared to pH adjustment alone. Empirical models showed increased total phosphorus, pH, and alkalinity reduced iron release while increased silica, chloride, sulfate, and temperature contributed to iron release. Thermodynamic modeling suggested that FePO4 is the controlling solid that forms on iron and galvanized steel surfaces, regardless of blend, when OP inhibitor is added for corrosion control. While FePO4 does not offer much control of the iron release from the cast iron surfaces, it does offer protection of the galvanized steel surfaces reducing zinc release. OP inhibitor addition was found to reduce copper release for the OP dosages evaluated for the water blends evaluated compared to pH adjustment alone. Empirical models showed increases in total phosphorus, silica, and pH reduced copper release while increased alkalinity and chloride contributed to copper release. Thermodynamic modeling suggested that Cu3(PO4)22H2O is the controlling solid that forms on copper surfaces, regardless of blend, when OP inhibitor is added for corrosion control. OP inhibitor addition was found to reduce lead release for the OP dosages evaluated for the water blends evaluated compared to pH adjustment alone. Empirical models showed increased total phosphorus and pH reduced lead release while increased alkalinity, chloride, and temperature contributed to lead release. Thermodynamic modeling suggested that hydroxypyromorphite is the controlling solid that forms on lead surfaces, regardless of blend, when OP inhibitor is added for corrosion control. The comparison of phosphate-based inhibitors found increasing pH to reduce iron, copper, and lead metal release, while increasing alkalinity was shown to reduce iron release but increase copper and lead release. The ZOP inhibitor was not predicted by the empirical models to perform as well as BOP and OP at the low dose of 0.5 mg/L as P for iron control, and the OP inhibitor was not predicted to perform as well as BOP and ZOP at the low dose of 0.5 mg/L as P for lead control. The three inhibitors evaluated performed similarly for copper control. Therefore, BOP inhibitor showed the lowest metal release at the low dose of 0.5 mg/L as P for control of iron, copper, and lead corrosion.
Show less - Date Issued
- 2008
- Identifier
- CFE0002382, ucf:47760
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002382