Current Search: Kassab, Alain (x) » Steward, Robert (x)
View All Items
- Title
- Fluid Dynamics Modeling and Sound Analysis of a Bileaflet Mechanical Heart Valve.
- Creator
-
Khalili, Fardin, Mansy, Hansen, Kassab, Alain, Steward, Robert, Zaurin, Ricardo, University of Central Florida
- Abstract / Description
-
Cardiovascular disease (CVD) is one of the main causes of death in the world. Some CVD involve severe heart valve disease that require valve replacement. There are more than 300,000 heart valves implanted worldwide, and about 85,000 heart valve replacements in the US. Approximately half of these valves are mechanical. Artificial valves may dysfunction leading to adverse hemodynamic conditions. Understanding the normal and abnormal valve function is important as it help improve valve designs....
Show moreCardiovascular disease (CVD) is one of the main causes of death in the world. Some CVD involve severe heart valve disease that require valve replacement. There are more than 300,000 heart valves implanted worldwide, and about 85,000 heart valve replacements in the US. Approximately half of these valves are mechanical. Artificial valves may dysfunction leading to adverse hemodynamic conditions. Understanding the normal and abnormal valve function is important as it help improve valve designs. Modeling of heart valve hemodynamics using computational fluid dynamics (CFD) provides a comprehensive analysis of flow, which can potentially help explain clinical observations and support therapeutic decision-making. This detailed information might not be accessible with in-vivo measurements. On the other hand, finite element analysis (FEA), is an efficient way to analyze the interactions of blood flow with blood vessel and tissue layers. In this project both CFD and FEA simulations were performed to investigate the flow-induced sound generation and propagation of sound waves through a tissue-like material. This method is based on mapping the transient pressure (force) fluctuations on the vessel wall and solving for the structural vibrations in the frequency domain. These vibrations would then be detected as sound on the epidermal surface. Advantages of the methods used in the current study include: (a) capability of providing accurate solution with a faster solution time; (b) inclusion of the fluid(-)structure interaction between blood flow and the arterial wall; and (c) accurately capturing some of the spectral features of the velocity fluctuation measured over the epidermal surface.
Show less - Date Issued
- 2018
- Identifier
- CFE0007029, ucf:52038
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0007029
- Title
- Probing the Influence of Cx43 and Glucose on Endothelial Biomechanics.
- Creator
-
Islam, Md Mydul, Steward, Robert, Kassab, Alain, Mansy, Hansen, Willenberg, Bradley, University of Central Florida
- Abstract / Description
-
Endothelial cells (ECs) form the innermost layer of all vasculature and constantly receive both biochemical and biomechanical signals, yielding a plethora of biomechanical responses. In response to various biochemical or biomechanical cues, ECs have been documented to generate biomechanical responses such as tractions and intercellular stresses between the cell and substrate and between adjacent cells in a confluent monolayer, respectively. Thus far, the ability of endothelial tight junctions...
Show moreEndothelial cells (ECs) form the innermost layer of all vasculature and constantly receive both biochemical and biomechanical signals, yielding a plethora of biomechanical responses. In response to various biochemical or biomechanical cues, ECs have been documented to generate biomechanical responses such as tractions and intercellular stresses between the cell and substrate and between adjacent cells in a confluent monolayer, respectively. Thus far, the ability of endothelial tight junctions and adherens junctions to transmit intercellular stresses has been actively investigated, but the role of gap junctions is currently unknown. In addition, there is no report of the independent influence of hyperglycemia on endothelial biomechanics present in the literature. To fill these gaps, we conducted a two-fold study where we investigated the influence of endothelial gap junction Cx43 and hyperglycemia in endothelial tractions and intercellular stress generation. In the first study, we selectively disrupted and enhanced EC gap junction Cx43 by using 2',5'-dihydroxychalcone and retinoic acid, respectively and in the second study, we cultured ECs in both normal glucose and hyperglycemic condition for 10 days. In both studies, tractions and intercellular stresses were calculated using traction force microscopy (TFM) and monolayer stress microscopy (MSM), respectively. Our results reveal that Cx43 downregulation increased as well as decreased endothelial avg. normal intercellular stresses in response to a low (0.83 (&)#181;M) and a high dose (8.3 (&)#181;M) chalcone treatment, respectively, while Cx43 upregulation decreases avg. normal intercellular stresses in both treatment conditions (2.5 (&)#181;M and 25 (&)#181;M) compared to control. In addition, we observed a decrease in intercellular stresses with hyperglycemic condition compared to control. The results we present here represent, for the first time, detailed and comprehensive biomechanical analysis of endothelial cells under the influence of glucose and the gap junction Cx43. We believe our results will provide valuable insights into endothelial permeability, barrier strength as well as leading to a greater understanding of overall endothelial mechanics.
Show less - Date Issued
- 2019
- Identifier
- CFE0007819, ucf:52805
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0007819
- Title
- Investigation of a Self-powered Fontan Concept Using a Multiscale Computational Fluid-Structure Interaction Model.
- Creator
-
Beggs, Kyle, Kassab, Alain, Steward, Robert, Mansy, Hansen, DeCampli, William, University of Central Florida
- Abstract / Description
-
Congenital Heart Disease (CHD) occurs in about 1\% (40,000) of newborn babies each year in the United States alone. About 10.9\% (960) of whom suffer from Hypoplastic Left Heart Syndrome (HLHS) - a subset of CHD where children are born with a single-ventricle (SV). A series of three surgeries are carried out to correct HLHS culminating in the Fontan procedure where venous flow returns passively to the lungs. The current configuration for the Fontan results in elevated Central Venous Pressure ...
Show moreCongenital Heart Disease (CHD) occurs in about 1\% (40,000) of newborn babies each year in the United States alone. About 10.9\% (960) of whom suffer from Hypoplastic Left Heart Syndrome (HLHS) - a subset of CHD where children are born with a single-ventricle (SV). A series of three surgeries are carried out to correct HLHS culminating in the Fontan procedure where venous flow returns passively to the lungs. The current configuration for the Fontan results in elevated Central Venous Pressure (CVP), inadequate ventricular preload, and elevated Pulmonary Vascular Resistance (PVR) leading to a barrage of disease. To alleviate these complications, a `self-powered' Fontan is suggested where an Injection Jet Shunt (IJS) emanating from the aorta is anastomosed to each pulmonary artery. The IJS attempts to reduce the central venous pressure, increase preload, and aid in pulmonary arterial growth by entraining the flow with a high energy source provided by the aorta. Previous computational studies on this concept with rigid vessel walls show mild success, but not enough to be clinically relevant. It is hypothesized that vessel wall deformation may play an important role in enhancing the jet effect to provide a larger exit area for the flow to diffuse while also being more physiologically accurate. A multiscale 0D-3D tightly coupled Computational Fluid Dynamics (CFD) with Fluid-Structure Interaction (FSI) model is developed to investigate the efficacy of the proposed `self-powered' Fontan modification. Several runs are made varying the PVR to investigate the sensitivity of IVC pressure on PVR. IVC pressure decreased by 2.41 mmHg while the rigid wall study decreased the IVC pressure by 2.88 mmHg. It is shown that IVC pressure is highly sensitive to changes in PVR and modifications to the Fontan procedure should target aiding pulmonary arterial growth as it is the main indicator of Fontan success.
Show less - Date Issued
- 2018
- Identifier
- CFE0007311, ucf:52107
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0007311