- Title
- Evaluation of an On-Line Device to Monitor Scale Formation in a Brackish Water Reverse Osmosis Membrane Process.
- Creator
-
Roque, Jennifer, Duranceau, Steven, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
A modified two-element membrane pressure vessel assembly has been used to monitor process operational changes in a full-scale reverse osmosis (RO) water treatment plant (WTP). This study evaluated the effectiveness of the assembly as an on-line monitoring device intended to detect scale formation conditions when connected to an operating RO process train. This study was implemented to support the requirements of a larger University of Central Florida (UCF) research project ongoing at the city...
Show moreA modified two-element membrane pressure vessel assembly has been used to monitor process operational changes in a full-scale reverse osmosis (RO) water treatment plant (WTP). This study evaluated the effectiveness of the assembly as an on-line monitoring device intended to detect scale formation conditions when connected to an operating RO process train. This study was implemented to support the requirements of a larger University of Central Florida (UCF) research project ongoing at the city of Sarasota's Public Works and Utilities (City) water treatment facilities located in Sarasota, Florida. During the time-frame of this study, the City was in the process of eliminating their sulfuric acid feed from the pretreatment system of their existing 4.5 million gallon per day (MGD) RO membrane process. The City was motivated to eliminate its dependence on sulfuric acid to reduce operating costs as well as reduce operation health and safety risks associated with the use of the acid as a pretreatment chemical. Because the City was concerned with secondary process impacts associated with acid elimination, additional measures were desired in order to protect the full-scale process.This thesis reports on the design, fabrication and installation of a third-stage two membrane element pressure vessel (")canary(") sentinel monitoring device (Canary), its effectiveness as an on-line scaling monitor during full-scale acid elimination, and presents the results of the study. The Canary sentinel device was controlled using the normalized specific flux of the two membrane elements fed by a portion of the second stage concentrate of one of the City's full-scale RO process skids. Although the Canary demonstrated the ability to detect changes in an RO process operation, scaling did not occur under the conditions evaluated in this study. An autopsy of one of the Canary elements revealed that no scaling had occurred during the acid elimination process. Therefore, the Canary was found to be useful in its function as a sentinel, even though no scaling was detected by the device after acid elimination at the City's full-scale plant had been accomplished.
Show less - Date Issued
- 2012
- Identifier
- CFE0004433, ucf:49353
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004433
- Title
- Evaluating Corrosion Control Alternatives for a Reverse Osmosis, Nanofiltration and Anion-Exchange Blended Water Supply.
- Creator
-
Wilder, Rebecca, Duranceau, Steven, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
The research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced...
Show moreThe research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced DBP formation potential, integration of the NF process altered finished water quality parameters including pH, alkalinity and hardness. There was concern that these changes could result in secondary impacts related to accelerated corrosion of distribution system components and subsequent regulatory compliance. In addition, replacement of the LS process altered the in-plant blending operations by creating an unstable intermediate blend composed of RO and IX waters. There were concerns that this intermediate blend was affecting the integrity of in-plant hydraulic conveyance components.UCF developed a corrosion monitoring study to assess the potential impacts related to internal corrosion, water quality and regulatory compliance after integrating NF into the existing water supply. The intended purpose was to further highlight the complexities of corrosion, describe a unique approach to corrosion monitoring as well as offer various recommendations for corrosion control in a system that relies on a blended water supply. Research was conducted in three phases to address the in-plant and distribution system corrosion issues separately and identify appropriate corrosion control treatment alternatives. The three test phases included: a baseline conditions assessment to compare corrosion of the intermediate RO-IX blend with the finished water blend (RO-IX-NF); an in-plant corrosion control evaluation; and a distribution system corrosion control evaluation.A test apparatus was constructed and operated at the Town's facilities to monitor corrosion activity of mild steel, copper and lead solder metal components. The test apparatus consisted of looped PVC pipe segments housed with electrochemical probes and metal coupons to monitor corrosion rates of the metallic components. Electrochemical probes containing metal electrodes were used to obtain instantaneous corrosion rates by means of the Linear Polarization Resistance (LPR) technique while the metal coupons were gravimetrically evaluated for weight loss. The electrochemical probes permitted daily monitoring of each metal's corrosion rates while metal coupons were analyzed at the conclusion of testing and used for comparison. Different test waters flowed through the corrosion rack according to each test phase and relative corrosion rates were compared to evaluate corrosion control techniques.Study findings indicated that the intermediate blend was more corrosive, in general, then the final blend; however, research also indicated that the final blend of water was increasing lead and copper concentrations within the distribution system. An orthophosphate corrosion inhibitor was evaluated for in-plant corrosion control. The inhibitor's performance was assessed by comparing mild steel corrosion rates with and without the chemical. In addition, secondary impacts related to introduction of the chemical were evaluated by pre-corroding the metallic components prior to the introduction of the inhibitor. Results indicated that the inhibitor marginally decreased corrosion rates and increased the turbidity of the water supply. Based on these observations, it was concluded that the inhibitor was not a viable solution for in-plant corrosion control. To resolve in-plant corrosion issues, recommendations were made for modification of in-plant blending operations to eliminate the corrosive intermediate blend from the process allowing the RO, IX and NF treated waters to be blended in a common location. The effectiveness of a poly/ortho blended phosphate chemical inhibitor was evaluated for reducing lead and copper corrosion to resolve distribution corrosion issues. A 50/50 poly/ortho blend was selected because of its analogous use in similar municipal water facilities. Metallic corrosion rates, particularly lead and copper, were compared with and without the inhibitor to assess the performance of the chemical. Like the previous test phase, the metallic components were pre-corroded prior to the chemical's introduction to determine if secondary impacts could result from its presence. Results indicated that lead and copper corrosion rates were lower in the presence of the inhibitor, and secondary impacts related to increased turbidity were not observed for this chemical. Based on these results, it was recommended that a poly/ortho blended phosphate be used to decrease lead and copper corrosion within the Town's distribution system.
Show less - Date Issued
- 2012
- Identifier
- CFE0004460, ucf:49349
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004460
- Title
- Monitoring and Modeling to Estimate Hydrogen Sulfide Emissions and Dispersion from Florida Construction and Demolition Landfills to Construct Odor Buffering Distances.
- Creator
-
Bolyard, Steven, Cooper, Charles, Mackie, Kevin, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
Emissions of hydrogen sulfide (H2S) from construction and demolition (C & D) landfills can result in odors that are a significant nuisance to nearby neighborhoods and businesses. As Florida's population continues to grow and create development pressures, housing is built closer to existing landfills. Additionally, new landfills will be created in the future. This research project was undertaken to develop a detailed modeling methodology for use by counties and other landfill owners to provide...
Show moreEmissions of hydrogen sulfide (H2S) from construction and demolition (C & D) landfills can result in odors that are a significant nuisance to nearby neighborhoods and businesses. As Florida's population continues to grow and create development pressures, housing is built closer to existing landfills. Additionally, new landfills will be created in the future. This research project was undertaken to develop a detailed modeling methodology for use by counties and other landfill owners to provide them with an objective and scientifically defensible means to establish odor buffer zones around C & D landfills. A technique for estimating methane (and odorous gas) emissions from municipal solid waste (MSW) landfills was recently developed by researchers at the University of Central Florida. This technique was based on measuring hundreds of ambient methane concentrations near the surface of the landfill, and combining that data with matrix inversion mathematics to back-solve the dispersion equations. The technique was fully documented in two peer-reviewed journal articles. This project extends that methodology. In this work the author measured ambient H2S concentrations at various locations in a C & D landfill, and applied those same matrix inversion techniques to determine the H2S emission rates from the landfill. The emission rates were then input into the AERMOD dispersion model to determine H2S odor buffer distances around the landfill.Three sampling trips to one C & D landfill were undertaken, data were taken, and the modeling techniques were applied. One problem encountered was that H2S emissions from C & D landfills are typically about 1000 times smaller than methane emissions (from MSW landfills). Thus, H2S ambient concentrations often are near the detection limits of the instruments, and the data may not be as reliable. However, this approach could be used for any particular C & D landfill if the appropriate amount of data were available to characterize its emissions with some certainty. The graphical tool developed in this work shows isopleths of (")H2S(") concentrations at various distances, and color codes the isopleths into a (")green-yellow-red(") scheme (analogous to a traffic signal) that depicts zones where private landowners likely will not detect odors, where they may experience some odors, or where they likely will experience odors. The (")likelihood(") can be quantified by selecting the Nth highest hourly concentrations in one year to form the plot. In this study, N was conservatively selected as 8. Requiring that concentrations be at or below the 8th highest concentration in a year corresponds to a 99.9% probability of not exceeding that concentration at that distance in any future year. The graphical tool can be applied to any C & D landfill but each landfill is different. So this technique depends on having a fairly good estimate of the rate of emissions of H2S from the landfill in question, and at least one year's worth of hourly meteorological data (wind speed, direction, and stability class) that is representative of the landfill location. The meteorological data can be obtained with relative ease for most locations in Florida; however, the emission data must be obtained from on-site measurements for any given landfill.
Show less - Date Issued
- 2012
- Identifier
- CFE0004272, ucf:52879
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004272