Current Search: heat transfer augmentation (x)
View All Items
- Title
- EFFECT OF RIB ASPECT RATIO ON HEAT TRANSFER AND FRICTION IN RECTANGULAR CHANNELS.
- Creator
-
Tran, Lucky, kapat, Jay, University of Central Florida
- Abstract / Description
-
The heat transfer and friction augmentation in the fully developed portion of a 2:1 aspect ratio rectangular channel with orthogonal ribs at channel Reynolds numbers of 20,000, 30,000, and 40,000 is studied both experimentally and computationally. Ribs are applied to the two opposite wide walls. The rib aspect ratio is varied systematically at 1, 3, and 5, with a constant rib height and constant rib pitch (rib-pitch-to-rib-height ratio of 10). The purpose of the study is to extend the...
Show moreThe heat transfer and friction augmentation in the fully developed portion of a 2:1 aspect ratio rectangular channel with orthogonal ribs at channel Reynolds numbers of 20,000, 30,000, and 40,000 is studied both experimentally and computationally. Ribs are applied to the two opposite wide walls. The rib aspect ratio is varied systematically at 1, 3, and 5, with a constant rib height and constant rib pitch (rib-pitch-to-rib-height ratio of 10). The purpose of the study is to extend the knowledge of the performance of rectangular channels with ribs to include high aspect ratio ribs. The experimental investigation is performed using transient Thermochromic Liquid Crystals technique to measure the distribution of the local Nusselt numbers on the ribbed walls. Overall channel pressure drop and friction factor augmentation is also obtained with the experimental setup. A numerical simulation is also performed by solving the 3-D Reynolds-averaged Navier-Stokes equations using the realizable-k-[episilon] turbulence model for closure. Flow visualization is obtained from the computational results as well as numerical predictions of local distributions of Nusselt numbers and overal channel pressure drop. Results indicate that with increasing rib width, the heat transfer augmentation of the ribbed walls decreases with a corresponding reduction in channel pressure drop.
Show less - Date Issued
- 2011
- Identifier
- CFH0004103, ucf:44890
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFH0004103
- Title
- Surface Measurements and Predictions of Full-Coverage Film Cooling.
- Creator
-
Natsui, Gregory, Kapat, Jayanta, Raghavan, Seetha, Vasu Sumathi, Subith, University of Central Florida
- Abstract / Description
-
Full-coverage film cooling is investigated both experimentally and numerically. First,surface measurements local of adiabatic film cooling eeffectiveness and heat transfer augmentation for four different arrays are described. Reported next is a comparison between two very common turbulence models, Realizable k-epsilon and SST k-omega, and their ability to predict local film cooling effectiveness throughout a full-coverage array.The objective of the experimental study is the quantification of...
Show moreFull-coverage film cooling is investigated both experimentally and numerically. First,surface measurements local of adiabatic film cooling eeffectiveness and heat transfer augmentation for four different arrays are described. Reported next is a comparison between two very common turbulence models, Realizable k-epsilon and SST k-omega, and their ability to predict local film cooling effectiveness throughout a full-coverage array.The objective of the experimental study is the quantification of local heat transferaugmentation and adiabatic film cooling effectiveness for four surfaces cooled by large, both in hole count and in non-dimensional spacing, arrays of film cooling holes. The four arrays are of two different hole-to-hole spacings (P=D = X=D = 14.5; 19.8) and two different hole inclination angles (alpha = 30°; 45°), with cylindrical holes compounded relative to the flow(beta = 45°) and arranged in a staggered configuration. Arrays of up to 30 rows are tested so that the superposition effect of the coolant film can be studied. In addition, shortened arrays of up to 20 rows of coolant holes are also tested so that the decay of the coolant film following injection can be studied.Levels of laterally averaged effectiveness reach values as high as η = 0.5, and are not yet at the asymptotic limit even after 20 - 30 rows of injection for all cases studied. Levels of heat transfer augmentation asymptotically approach values of h=h0 ≈ 1.35 rather quickly, only after 10 rows. It is conjectured that the heat transfer augmentation levels off very quickly due to the boundary layer reaching an equilibrium in which the perturbation from additional film rows has reached a balance with the damping effect resulting from viscosity. The levels of laterally averaged adiabatic film cooling effectiveness far exceeding eta = 0.5 aremuch higher than expected. The heat transfer augmentation levels off quickly as opposed tothe film effectiveness which continues to rise (although asymptotically) at large row numbers. This ensures that an increased row count represents coolant well spent.The numerical predictions are carried out in order to test the ability of the two mostcommon turbulence models to properly predict full-coverage film cooling. The two models chosen, Realizable k-epsilon (RKE) and Shear Stress Transport k-omega (SSTKW), areboth two-equation models coupled with Reynolds Averaged governing equations which makeseveral gross physical assumptions and require several empirical values. Hence, the modelsare not expected to provide perfect results. However, very good average values are seen tobe obtained through these simple models. Using RKE in order to model full-coverage filmcooling will yield results with 30% less error than selecting SSTKW.
Show less - Date Issued
- 2012
- Identifier
- CFE0004580, ucf:49221
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004580