Current Search: Optical coherence tomography (x)
View All Items
- Title
- DESIGN OF A DYNAMIC FOCUSING MICROSCOPE OBJECTIVE FOR OCT IMAGING.
- Creator
-
Murali, Supraja, Rolland, Jannick, University of Central Florida
- Abstract / Description
-
Optical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique ultrasound. In this thesis, high resolution OCT is investigated for in vivo detection of abnormal skin pathology for the early...
Show moreOptical Coherence Tomography (OCT) is a novel optical imaging technique that has assumed significant importance in bio-medical imaging in the last two decades because it is non-invasive and provides accurate, high resolution images of three dimensional cross-sections of body tissue, exceeding the capabilities of the current predominant imaging technique ultrasound. In this thesis, high resolution OCT is investigated for in vivo detection of abnormal skin pathology for the early diagnosis of cancer. The technology presented is based on a dynamic focusing microscopic imaging probe conceived for skin imaging and the detection of abnormalities in the epithelium. A novel method for dynamic focusing in the biological sample using liquid crystal (LC) lens technology to obtain three dimensional images with invariant resolution throughout the cross-section and depth of the sample is presented and discussed. Two different skin probe configurations that incorporate dynamic focusing with LC lenses, one involving a reflective microscope objective sub-system, and the other involving an all-refractive immersion microscope objective sub-system are investigated. In order to ensure high resolution imaging, a low coherence broadband source, namely a femtosecond mode-locked Ti: sapphire laser centered at a wavelength of approximately 800nm is used to illuminate the sample. An in-depth description and analysis of the optical design and predicted performance of the two microscope objectives designed for dynamic three dimensional imaging at 5ìm resolution for the chosen broadband spectrum is presented.
Show less - Date Issued
- 2005
- Identifier
- CFE0000869, ucf:46665
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0000869
- Title
- SYSTEM DESIGN AND OPTIMIZATION OF OPTICAL COHERENCE TOMOGRAPHY.
- Creator
-
Akcay, Avni, Rolland, Jannick, University of Central Florida
- Abstract / Description
-
Optical coherence imaging, including tomography (OCT) and microscopy (OCM), has been a growing research field in biomedical optical imaging in the last decade. In this imaging modality, a broadband light source, thus of short temporal coherence length, is used to perform imaging via interferometry. A challenge in optical coherence imaging, as in any imaging system towards biomedical diagnosis, is the quantification of image quality and optimization of the system components, both a primary...
Show moreOptical coherence imaging, including tomography (OCT) and microscopy (OCM), has been a growing research field in biomedical optical imaging in the last decade. In this imaging modality, a broadband light source, thus of short temporal coherence length, is used to perform imaging via interferometry. A challenge in optical coherence imaging, as in any imaging system towards biomedical diagnosis, is the quantification of image quality and optimization of the system components, both a primary focus of this research. We concentrated our efforts on the optimization of the imaging system from two main standpoints: axial point spread function (PSF) and practical steps towards compact low-cost solutions. Up to recently, the criteria for the quality of a system was based on speed of imaging, sensitivity, and particularly axial resolution estimated solely from the full-width at half-maximum (FWHM) of the axial PSF with the common practice of assuming a Gaussian source power spectrum. As part of our work to quantify axial resolution we first brought forth two more metrics unlike FWHM, which accounted for side lobes in the axial PSF caused by irregularities in the shape of the source power spectrum, such as spectral dips. Subsequently, we presented a method where the axial PSF was significantly optimized by suppressing the side lobes occurring because of the irregular shape of the source power spectrum. The optimization was performed through optically shaping the source power spectrum via a programmable spectral shaper, which consequentially led to suppression of spurious structures in the images of a layered specimen. The superiority of the demonstrated approach was in performing reshaping before imaging, thus eliminating the need for post-data acquisition digital signal processing. Importantly, towards the optimization and objective image quality assessment in optical coherence imaging, the impact of source spectral shaping was further analyzed in a task-based assessment method based on statistical decision theory. Two classification tasks, a signal-detection task and a resolution task, were investigated. Results showed that reshaping the source power spectrum was a benefit essentially to the resolution task, as opposed to both the detection and resolution tasks, and the importance of the specimen local variations in index of refraction on the resolution task was demonstrated. Finally, towards the optimization of OCT and OCM for use in clinical settings, we analyzed the detection electronics stage, which is a crucial component of the system that is designed to capture extremely weak interferometric signals in biomedical and biological imaging applications. We designed and tested detection electronics to achieve a compact and low-cost solution for portable imaging units and demonstrated that the design provided an equivalent performance to the commercial lock-in amplifier considering the system sensitivity obtained with both detection schemes.
Show less - Date Issued
- 2005
- Identifier
- CFE0000651, ucf:46527
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0000651
- Title
- DEVELOPMENT OF OPTICAL COHERENCE TOMOGRAPHY FOR TISSUE DIAGNOSTICS.
- Creator
-
Meemon, Panomsak, Rolland, Jannick, University of Central Florida
- Abstract / Description
-
Microvasculature can be found in almost every part of the human body, including the internal organs. Importantly, abnormal changes in microvasculature are usually related to pathological development of the tissue cells. Monitoring of changes in blood flow properties in microvasculature, therefore, provides useful diagnostic information about pathological conditions in biological tissues as exemplified in glaucoma, diabetes, age related macular degeneration, port wine stains, burn-depth, and...
Show moreMicrovasculature can be found in almost every part of the human body, including the internal organs. Importantly, abnormal changes in microvasculature are usually related to pathological development of the tissue cells. Monitoring of changes in blood flow properties in microvasculature, therefore, provides useful diagnostic information about pathological conditions in biological tissues as exemplified in glaucoma, diabetes, age related macular degeneration, port wine stains, burn-depth, and potentially skin cancer. However, the capillary network is typically only one cell in wall thickness with 5 to 10 microns in diameter and located in the dermis region of skin. Therefore, a non-invasive flow imaging technique that is capable of depth sectioning at high resolution and high speed is demanded. Optical coherence tomography (OCT), particularly after its advancement in frequency domain OCT (FD-OCT), is a promising tool for non-invasive high speed, high resolution, and high sensitivity depth-resolved imaging of biological tissues. Over the last ten years, numerous efforts have been paid to develop OCT-based flow imaging techniques. An important effort is the development of phase-resolved Doppler OCT (PR-DOCT). Phase-resolved Doppler imaging using FD-OCT is particularly of interest because of the direct access to the phase information of the depth profile signal. Furthermore, the high speed capability of FD-OCT is promising for real time flow monitoring as well as 3D flow segmentation applications. However, several challenges need to be addressed; 1) Flow in biological samples exhibits a wide dynamic range of flow velocity caused by, for example, the variation in the flow angles, flow diameters, and functionalities. However, the improvement in imaging speed of FD-OCT comes at the expense of a reduction in sensitivity to slow flow information and hence a reduction in detectable velocity range; 2) A structural ambiguity so-called 'mirror image' in FD-OCT prohibits the use of maximum sensitivity and imaging depth range; 3) The requirement of high lateral resolution to resolve capillary vessels requires the use of an imaging optics with high numerical aperture (NA) that leads to a reduction in depth of focus (DOF) and hence the imaging depth range (i.e. less than 100 microns) unless dynamic focusing is performed. Nevertheless, intrinsic to the mechanism of FD-OCT, dynamic focusing is not possible. In this dissertation, the implementation of PR-DOCT in a high speed swept-source based FD-OCT is investigated and optimized. An acquisition scheme as well as a processing algorithm that effectively extends the detectable velocity dynamic range of the PR-DOCT is presented. The proposed technique increased the overall detectable velocity dynamic range of PR-DOCT by about five times of that achieved by the conventional method. Furthermore, a novel technique of mirror image removal called ÃÂ'Dual-Detection FD-OCTÃÂ' (DD-FD-OCT) is presented. One of the advantages of DD-FD-OCT to Doppler imaging is that the full-range signal is achieved without manipulation of the phase relation between consecutive axial lines. Hence the full-range DD-FD-OCT is fully applicable to phase-resolved Doppler detection without a reduction in detectable velocity dynamic range as normally encountered in other full-range techniques. In addition, PR- DOCT can utilize the maximum signal-to-noise ratio provided by the full-range capability. This capability is particularly useful for imaging of blood flow that locates deep below the sample surface, such as blood flow at deep posterior human eye and blood vessels network in the dermis region of human skin. Beside high speed and functional imaging capability, another key parameter that will open path for optical diagnostics using OCT technology is high resolution imaging (i.e. in a regime of a few microns or sub-micron). Even though the lateral resolution of OCT can be independently improved by opening the NA of the imaging optics, the high lateral resolution is maintained only over a short range as limited by the depth of focus that varies inversely and quadratically with NA. Recently developed by our group, ÃÂ'Gabor-Domain Optical Coherence MicroscopyÃÂ' (GD-OCM) is a novel imaging technique capable for invariant resolution of about 2-3 microns over a 2 mm cubic field-of-view. This dissertation details the imaging protocol as well as the automatic data fusion method of GD-OCM developed to render an in-focus high-resolution image throughout the imaging depth of the sample in real time. For the application of absolute flow measurement as an example, the precise information about flow angle is required. GD-OCM provides more precise interpretation of the tissue structures over a large field-of-view, which is necessary for accurate mapping of the flow structure and hence is promising for diagnostic applications particularly when combined with Doppler imaging. Potentially, the ability to perform high resolution OCT imaging inside the human body is useful for many diagnostic applications, such as providing an accurate map for biopsy, guiding surgical and other treatments, monitoring the functional state and/or the post-operative recovery process of internal organs, plaque detection in arteries, and early detection of cancers in the gastrointestinal tract. Endoscopic OCT utilizes a special miniature probe in the sample arm to access tubular organs inside the human body, such as the cardiovascular system, the lung, the gastrointestinal tract, the urinary tract, and the breast duct. We present an optical design of a dynamic focus endoscopic probe that is capable of about 4 to 6 microns lateral resolution over a large working distance (i.e. up to 5 mm from the distal end of the probe). The dynamic focus capability allows integration of the endoscopic probe to GD-OCM imaging to achieve high resolution endoscopic tomograms. We envision the future of this developing technology as a solution to high resolution, minimally invasive, depth-resolved imaging of not only structure but also the microvasculature of in vivo biological tissues that will be useful for many clinical applications, such as dermatology, ophthalmology, endoscopy, and cardiology. The technology is also useful for animal study applications, such as the monitoring of an embryoÃÂ's heart for the development of animal models and monitoring of changes in blood circulation in response to external stimulus in small animal brains.
Show less - Date Issued
- 2010
- Identifier
- CFE0003442, ucf:48392
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0003442
- Title
- EXTENDED FOCUS RANGE HIGH RESOLUTION ENDOSCOPIC OPTICAL COHERENCE TOMOGRAPHY.
- Creator
-
Lee, Kye-Sung, Rolland, Jannick, University of Central Florida
- Abstract / Description
-
Today, medical imaging is playing an important role in medicine as it provides the techniques and processes used to create images of the human body or parts thereof for clinical purposes (medical procedures seeking to reveal, diagnose or examine disease) or medical science (including the study of normal anatomy and function). Modalities are developing over time to achieve the highest possible resolution, speed of image acquisition, sensitivity, and specificity. In the past decade, advances in...
Show moreToday, medical imaging is playing an important role in medicine as it provides the techniques and processes used to create images of the human body or parts thereof for clinical purposes (medical procedures seeking to reveal, diagnose or examine disease) or medical science (including the study of normal anatomy and function). Modalities are developing over time to achieve the highest possible resolution, speed of image acquisition, sensitivity, and specificity. In the past decade, advances in optics, fiber, as well as laser technology have enabled the development of noninvasive optical biomedical imaging technology that can also be applied to endoscopy to reach deeper locations in the human body. The purpose of this dissertation is to investigate a full system design and optimization of an optical coherence tomography (OCT) system to achieve high axial and lateral resolution together with an extended depth of focus for endoscopic in vivo imaging. In this research aimed at advancing endoscopic OCT imaging, two high axial resolution optical coherence tomography systems were developed: (1) a spectrometer-based frequency-domain (FD) OCT achieving an axial resolution of ~2.5 µm using a Ti:Sa femtosecond laser with a 120nm bandwidth centered at 800nm and (2) a swept-source based FD OCT employing a high speed Fourier domain mode locked (FDML) laser that achieves real time in vivo imaging with ~8 µm axial resolution at an acquisition speed of 90,000 A-scans/sec. A critical prior limitation of FD OCT systems is the presence of mirror images in the image reconstruction algorithm that could only be eliminated at the expense of depth and speed of imaging. A key contribution of this research is the development of a novel FD OCT imager that enables full range depth imaging without a loss in acquisition speed. Furthermore, towards the need for better axial resolution, we developed a mathematical model of the OCT signal that includes the effect on phase modulation of phase delay, group delay, and dispersion. From the mathematical model we saw that a Fourier domain optical delay line (FD ODL) incorporated into the reference arm of the OCT system represented a path to higher performance. Here we then present a method to compensate for overall system dispersion with a FDODL that maintains the axial resolution at the limit determined solely by the coherence length of a broadband source. In the development of OCT for endoscopic applications, the need for long depth of focus imaging is critical to accommodate the placement of the catheter anywhere within a vessel. A potential solution to this challenge is Bessel-beam imaging. In a first step, a Bessel-beam based confocal scanning optical microscopy (BCSOM) using an axicon and single mode fiber was investigated with a mathematical model and simulation. The BCSOM approach was then implemented in a FD OCT system that delivered high lateral resolution over a long depth of focus. We reported on the imaging in biological samples for the first time with a double-pass microoptics axicon that demonstrated clearly invariant SNR and 8 um lateral resolution images across a 4 mm depth of focus. Finally, we describe the design and fabrication of a catheter incorporated in the FD OCT. The design, conceived for a 5 mm outer diameter catheter, allows 360 degree scanning with a lateral resolution of about 5 um across a depth of focus of about 1.6 mm. The dissertation concludes with comments for related future work.
Show less - Date Issued
- 2008
- Identifier
- CFE0002461, ucf:47721
- Format
- Document (PDF)
- PURL