Current Search: blended orthophosphate (x)
View All Items
- Title
- REVERSION OF POLY-PHOSPHATES TO ORTHO-PHOSPHATES IN WATER DISTRIBUTION SYSTEMS.
- Creator
-
shekhar, avinash, taylor, james, University of Central Florida
- Abstract / Description
-
Orthophosphates and polyphosphates are rarely present at significant levels in raw water source but are purposefully added to the water in various forms to inhibit corrosion, iron oxidation (red water), or calcium carbonate precipitation (scale formation). Orthophosphates serve as building blocks for polyphosphates, which includes structures in linear chain, branched chains (metaphosphate) and "glassy" polyphosphate polymers. The advantage of polyphosphates over ortho phosphates lies in the...
Show moreOrthophosphates and polyphosphates are rarely present at significant levels in raw water source but are purposefully added to the water in various forms to inhibit corrosion, iron oxidation (red water), or calcium carbonate precipitation (scale formation). Orthophosphates serve as building blocks for polyphosphates, which includes structures in linear chain, branched chains (metaphosphate) and "glassy" polyphosphate polymers. The advantage of polyphosphates over ortho phosphates lies in the fact that they slowly revert to orthophosphates and thus provide corrosion inhibition action over longer period of time in distribution systems. A study was completed for Tampa Bay Water on water distribution systems in a changing water quality environment. Blended orthophosphates was used as one of the corrosion inhibitors to study its effects on metal release and thus justify its application in comparison to other corrosion inhibitors like orthophosphates, zinc orthophosphates and silicates. This work focuses on the study of reversion of polyphosphates to ortho phosphates. A first-order model was developed that quantifies reversion as a function of the hydraulic residence time and initial poly phosphate concentration. The same model was used in two different forms one for the hybrid lines and the other for single material lines. The results from single material lines (estimated by a non linear least square regression using ANOVA) showed that the reversion rate was highest for galvanized pipe followed by unlined cast iron, lined cast iron and the lowest rate in PVC. The first-order reversion rate constant in PVC was almost two log orders less than galvanized line. A high first-order rate constant for the galvanized pipe could be attributed to a rougher surface, large surface area, reaction with the wall surface, pipe material or a combination of these effects. The results from the hybrid PDSs (estimated by an algebraic manipulation of the first-order reaction) substantially agree with the results obtained from the single material lines, with the exception of the PVC material. The data from the hybrid lines confirms that the reversion rate constant is greatest for exposure to galvanized pipe materials, but the hybrid data indicate that the rate constant associated with PVC is somewhat larger than the constants determined for either LCI or UCI. Once an overall first-order rate expression was established, efforts were made to find a relation between polyphosphate reversions with bulk water quality. None of the major water quality parameters were found to significantly affect the reversion. This observation may be attributable to a similar water quality over the study duration. A positive correlation was found between first-order reversion rate constant and temperature. An empirical equation (modified Arrhenius equation) that relates the first-order reversion rate constant with temperature was developed that showed a strong sensitivity to temperature. The results from this study could be used to predict the stability of polyphosphates in distribution systems with varying pipe materials and temperature.
Show less - Date Issued
- 2007
- Identifier
- CFE0001832, ucf:47350
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0001832
- Title
- IMPACT OF CORROSION INHIBITOR BLENDED ORTHOPHOSPHATE ON WATER QUALITY IN WATER DISTRIBUTION SYSTEMS.
- Creator
-
Alshehri, Abdulrahman, Taylor, James, University of Central Florida
- Abstract / Description
-
The impact of blended orthophosphate (BOP) inhibitor addition on the corrosion of iron, copper, and lead in drinking water distribution systems was studied under changing water quality environment. Release of iron, copper, and lead were monitored at varying inhibitor doses and changing blends of source waters (groundwater, surface water, and desalinated water). Solid corrosion products on pipe surfaces under BOP treatment were evaluated with surface characterization techniques. Performance of...
Show moreThe impact of blended orthophosphate (BOP) inhibitor addition on the corrosion of iron, copper, and lead in drinking water distribution systems was studied under changing water quality environment. Release of iron, copper, and lead were monitored at varying inhibitor doses and changing blends of source waters (groundwater, surface water, and desalinated water). Solid corrosion products on pipe surfaces under BOP treatment were evaluated with surface characterization techniques. Performance of the BOP inhibitor was compared to other corrosion control strategies. Iron scales for iron and galvanized steel coupons incubated in different blended waters in the presence of BOP inhibitor were analyzed by X-ray Photoelectron Spectroscopy (XPS) for surface composition. Identified iron corrosion products were ferric oxide (Fe2O3), magnetite (Fe3O4), and hydrated ferric oxide (FeOOH), in addition to ferric phosphate (FePO4) on coupons exposed to BOP inhibitor. Variations of water quality did not significantly affect the distribution of solid iron forms on surface films. Thermodynamic modeling indicated siderite (FeCO3) was the controlling solid phase of iron release. XPS indicated addition of BOP inhibitor produced a solid phosphate film in the iron scale which could inhibit iron release. Impact of BOP, orthophosphate, and pH adjustment on iron release in a distribution system was examined. Iron release was sensitive to water quality variations (alkalinity and chloride) associated with source and blends of finished water. Finished waters with high alkalinity content (between 149 and 164 mg/L as CaCO3) consistently mitigated iron release regardless of inhibitor use. Dissolved iron constituted about 10% of total iron release. Empirical models were developed that related water quality, inhibitor type and dose to iron release. The BOP inhibitor minimized total iron release followed closely by increasing pH (between 7.9 and 8.1), while orthophosphate dose did not affect iron release. Temperature (ranged from 21.2 to 25.3) had limited influence on iron release with BOP treatment. Monitoring copper release showed that dissolved copper was the dominant form in the effluent, at about 88%. BOP inhibitor doses of 0.5 to 2.0 mg/L proved beneficial in controlling copper concentrations to an average of below 0.5 mg/L. Control of copper release improved with increasing BOP dose, despite changes in alkalinity. Elevation of pH by 0.3 unit beyond pHs (between 7.9 and 8.1) resulted in noticeable decrease in copper concentrations of about 30%, but was more sensitive to higher alkalinity (146 to 151 mg/L as CaCO3) than BOP treatment. Developed empirical models confirmed the importance of BOP inhibitor dose, pH increase, and alkalinity content on copper release. Statistical comparison of the corrosion control strategies proved the advantage of BOP inhibitor, at all doses, over pH elevation in controlling copper release. The BOP inhibitor mitigated lead release below action level, and consistently outperformed pH elevation, in all water quality conditions. XPS analysis identified lead dioxide (PbO2), lead oxide (PbO), cerussite (PbCO3), and hydrocerussite (Pb3(CO3)2(OH)2) as the corrosion products in the scale of lead/tin coupons exposed to BOP inhibitor. XPS and Scanning Electron Microscopy (SEM) analysis suggested cerussite or hydrocerussite is the controlling solid phase of lead release. Thermodynamic models for cerussite and hydrocerussite grossly over predicted actual concentrations. Solubility and equilibrium relationships suggested the possibility of a lead orthophosphate solid that would describe the effectiveness of BOP inhibitor, although no lead-phosphate solid was detected by surface analysis. BOP inhibitor appeared to have mitigated lead release by forming a surface film between lead scale and the bulk water.