- DEVELOPMENT OF OPTICAL COHERENCE TOMOGRAPHY FOR TISSUE DIAGNOSTICS.
- Creator
-
Meemon, Panomsak, Rolland, Jannick, University of Central Florida
- Abstract / Description
-
Microvasculature can be found in almost every part of the human body, including the internal organs. Importantly, abnormal changes in microvasculature are usually related to pathological development of the tissue cells. Monitoring of changes in blood flow properties in microvasculature, therefore, provides useful diagnostic information about pathological conditions in biological tissues as exemplified in glaucoma, diabetes, age related macular degeneration, port wine stains, burn-depth, and...
Show moreMicrovasculature can be found in almost every part of the human body, including the internal organs. Importantly, abnormal changes in microvasculature are usually related to pathological development of the tissue cells. Monitoring of changes in blood flow properties in microvasculature, therefore, provides useful diagnostic information about pathological conditions in biological tissues as exemplified in glaucoma, diabetes, age related macular degeneration, port wine stains, burn-depth, and potentially skin cancer. However, the capillary network is typically only one cell in wall thickness with 5 to 10 microns in diameter and located in the dermis region of skin. Therefore, a non-invasive flow imaging technique that is capable of depth sectioning at high resolution and high speed is demanded. Optical coherence tomography (OCT), particularly after its advancement in frequency domain OCT (FD-OCT), is a promising tool for non-invasive high speed, high resolution, and high sensitivity depth-resolved imaging of biological tissues. Over the last ten years, numerous efforts have been paid to develop OCT-based flow imaging techniques. An important effort is the development of phase-resolved Doppler OCT (PR-DOCT). Phase-resolved Doppler imaging using FD-OCT is particularly of interest because of the direct access to the phase information of the depth profile signal. Furthermore, the high speed capability of FD-OCT is promising for real time flow monitoring as well as 3D flow segmentation applications. However, several challenges need to be addressed; 1) Flow in biological samples exhibits a wide dynamic range of flow velocity caused by, for example, the variation in the flow angles, flow diameters, and functionalities. However, the improvement in imaging speed of FD-OCT comes at the expense of a reduction in sensitivity to slow flow information and hence a reduction in detectable velocity range; 2) A structural ambiguity so-called 'mirror image' in FD-OCT prohibits the use of maximum sensitivity and imaging depth range; 3) The requirement of high lateral resolution to resolve capillary vessels requires the use of an imaging optics with high numerical aperture (NA) that leads to a reduction in depth of focus (DOF) and hence the imaging depth range (i.e. less than 100 microns) unless dynamic focusing is performed. Nevertheless, intrinsic to the mechanism of FD-OCT, dynamic focusing is not possible. In this dissertation, the implementation of PR-DOCT in a high speed swept-source based FD-OCT is investigated and optimized. An acquisition scheme as well as a processing algorithm that effectively extends the detectable velocity dynamic range of the PR-DOCT is presented. The proposed technique increased the overall detectable velocity dynamic range of PR-DOCT by about five times of that achieved by the conventional method. Furthermore, a novel technique of mirror image removal called ÃÂ'Dual-Detection FD-OCTÃÂ' (DD-FD-OCT) is presented. One of the advantages of DD-FD-OCT to Doppler imaging is that the full-range signal is achieved without manipulation of the phase relation between consecutive axial lines. Hence the full-range DD-FD-OCT is fully applicable to phase-resolved Doppler detection without a reduction in detectable velocity dynamic range as normally encountered in other full-range techniques. In addition, PR- DOCT can utilize the maximum signal-to-noise ratio provided by the full-range capability. This capability is particularly useful for imaging of blood flow that locates deep below the sample surface, such as blood flow at deep posterior human eye and blood vessels network in the dermis region of human skin. Beside high speed and functional imaging capability, another key parameter that will open path for optical diagnostics using OCT technology is high resolution imaging (i.e. in a regime of a few microns or sub-micron). Even though the lateral resolution of OCT can be independently improved by opening the NA of the imaging optics, the high lateral resolution is maintained only over a short range as limited by the depth of focus that varies inversely and quadratically with NA. Recently developed by our group, ÃÂ'Gabor-Domain Optical Coherence MicroscopyÃÂ' (GD-OCM) is a novel imaging technique capable for invariant resolution of about 2-3 microns over a 2 mm cubic field-of-view. This dissertation details the imaging protocol as well as the automatic data fusion method of GD-OCM developed to render an in-focus high-resolution image throughout the imaging depth of the sample in real time. For the application of absolute flow measurement as an example, the precise information about flow angle is required. GD-OCM provides more precise interpretation of the tissue structures over a large field-of-view, which is necessary for accurate mapping of the flow structure and hence is promising for diagnostic applications particularly when combined with Doppler imaging. Potentially, the ability to perform high resolution OCT imaging inside the human body is useful for many diagnostic applications, such as providing an accurate map for biopsy, guiding surgical and other treatments, monitoring the functional state and/or the post-operative recovery process of internal organs, plaque detection in arteries, and early detection of cancers in the gastrointestinal tract. Endoscopic OCT utilizes a special miniature probe in the sample arm to access tubular organs inside the human body, such as the cardiovascular system, the lung, the gastrointestinal tract, the urinary tract, and the breast duct. We present an optical design of a dynamic focus endoscopic probe that is capable of about 4 to 6 microns lateral resolution over a large working distance (i.e. up to 5 mm from the distal end of the probe). The dynamic focus capability allows integration of the endoscopic probe to GD-OCM imaging to achieve high resolution endoscopic tomograms. We envision the future of this developing technology as a solution to high resolution, minimally invasive, depth-resolved imaging of not only structure but also the microvasculature of in vivo biological tissues that will be useful for many clinical applications, such as dermatology, ophthalmology, endoscopy, and cardiology. The technology is also useful for animal study applications, such as the monitoring of an embryoÃÂ's heart for the development of animal models and monitoring of changes in blood circulation in response to external stimulus in small animal brains.
Show less - Date Issued
- 2010
- Identifier
- CFE0003442, ucf:48392
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0003442
- Title
- HYBRID AND HIERARCHICAL IMAGE REGISTRATION TECHNIQUES.
- Creator
-
Xu, Dongjiang, Kasparis, Takis, University of Central Florida
- Abstract / Description
-
A large number of image registration techniques have been developed for various types of sensors and applications, with the aim to improve the accuracy, computational complexity, generality, and robustness. They can be broadly classified into two categories: intensity-based and feature-based methods. The primary drawback of the intensity-based approaches is that it may fail unless the two images are misaligned by a moderate difference in scale, rotation, and translation. In addition,...
Show moreA large number of image registration techniques have been developed for various types of sensors and applications, with the aim to improve the accuracy, computational complexity, generality, and robustness. They can be broadly classified into two categories: intensity-based and feature-based methods. The primary drawback of the intensity-based approaches is that it may fail unless the two images are misaligned by a moderate difference in scale, rotation, and translation. In addition, intensity-based methods lack the robustness in the presence of non-spatial distortions due to different imaging conditions between images. In this dissertation, the image registration is formulated as a two-stage hybrid approach combining both an initial matching and a final matching in a coarse-to-fine manner. In the proposed hybrid framework, the initial matching algorithm is applied at the coarsest scale of images, where the approximate transformation parameters could be first estimated. Subsequently, the robust gradient-based estimation algorithm is incorporated into the proposed hybrid approach using a multi-resolution scheme. Several novel and effective initial matching algorithms have been proposed for the first stage. The variations of the intensity characteristics between images may be large and non-uniform because of non-spatial distortions. Therefore, in order to effectively incorporate the gradient-based robust estimation into our proposed framework, one of the fundamental questions should be addressed: what is a good image representation to work with using gradient-based robust estimation under non-spatial distortions. With the initial matching algorithms applied at the highest level of decomposition, the proposed hybrid approach exhibits superior range of convergence. The gradient-based algorithms in the second stage yield a robust solution that precisely registers images with sub-pixel accuracy. A hierarchical iterative searching further enhances the convergence range and rate. The simulation results demonstrated that the proposed techniques provide significant benefits to the performance of image registration.
Show less - Date Issued
- 2004
- Identifier
- CFE0000317, ucf:46294
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0000317
- Title
- FLOW VISUALIZATION IN MICROFLUIDIC EXPANSION AND MIXING.
- Creator
-
Yakhshi Tafti, Ehsan, Kumar, Ranganathan, University of Central Florida
- Abstract / Description
-
Micro particle image velocimetry (microPIV) is a non-intrusive tool for visualizing flow in micron-scale conduits. Using this investigative instrument, two experimental studies were performed to understand flow behaviors in microfluidic channels - a sudden expansion step flow and laminar velocity profile variation in diffusion driven mixing. First, flow in a backward facing step feature (1:5 expansion ratio) in a microchannel was taken as the subject of microPIV flow visualization. The onset...
Show moreMicro particle image velocimetry (microPIV) is a non-intrusive tool for visualizing flow in micron-scale conduits. Using this investigative instrument, two experimental studies were performed to understand flow behaviors in microfluidic channels - a sudden expansion step flow and laminar velocity profile variation in diffusion driven mixing. First, flow in a backward facing step feature (1:5 expansion ratio) in a microchannel was taken as the subject of microPIV flow visualization. The onset and development of a recirculation flow was studied as a function of flow rate. This flow pattern was further used to investigate two major parameters affecting microPIV measurements; the depth-of-focus and recording time-intervals between images in a microPIV image pair. The onset of recirculation was initiated at flow rates that correspond to Reynolds numbers, Re>95, which is well beyond the typical working range of microfluidic devices (Re=0.01-10). The recirculation flow has a 3D structure due to the dimensions of the microchannel and the effect of no slip condition on the walls. Ensemble cross-correlation was found not to be sensitive to variations of depth-of-focus and the output flow fields were similar as long as the overall optical focus remained within the upper and lower bounds of the microchannel. However, variations of time intervals between images in a microPIV pair, resulted in quantitatively and qualitatively different flow patterns for a given constant flow rate and depth-of-focus. In the second experiment, the effect of the laminar velocity profile and its variation on mixing phenomena at the reduced scale is studied. It is shown that the diffusive mass flux between two miscible streams, flowing in a laminar regime in a microchannel, is enhanced if the velocity at their diffusion interface is increased. Based on this idea, an in-plane passive micromixing concept is proposed and implemented in a working device (sigma micromixer). This mixer shows considerable mixing performance by periodically varying the flow velocity profile, such that the maximum of the profile coincides with the transversely progressing diffusion fronts repeatedly throughout the mixing channel. microPIV has been used to visualize the behavior of laminar flow inside the micromixer device and to confirm the periodic variation of the velocity profile through the mixing channel.
Show less - Date Issued
- 2009
- Identifier
- CFE0002826, ucf:48079
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002826
- Title
- TOWARDS CALIBRATION OF OPTICAL FLOW OF CROWD VIDEOS USING OBSERVED TRAJECTORIES.
- Creator
-
Elbadramany, Iman, Kaup, David, University of Central Florida
- Abstract / Description
-
The need exists for finding a quantitative method for validating crowd simulations. One approach is to use optical flow of videos of real crowds to obtain velocities that can be used for comparison to simulations. Optical flow, in turn, needs to be calibrated to be useful. It is essential to show that optical flow velocities obtained from crowd videos can be mapped into the spatially averaged velocities of the observed trajectories of crowd members, and to quantify the extent of the...
Show moreThe need exists for finding a quantitative method for validating crowd simulations. One approach is to use optical flow of videos of real crowds to obtain velocities that can be used for comparison to simulations. Optical flow, in turn, needs to be calibrated to be useful. It is essential to show that optical flow velocities obtained from crowd videos can be mapped into the spatially averaged velocities of the observed trajectories of crowd members, and to quantify the extent of the correlation of the results. This research investigates methods to uncover the best conditions for a good correlation between optical flow and the average motion of individuals in crowd videos, with the aim that this will help in the quantitative validation of simulations. The first approach was to use a simple linear proportionality relation, with a single coefficient, alpha, between velocity vector of the optical flow and observed velocity of crowd members in a video or simulation. Since there are many variables that affect alpha, an attempt was made to find the best possible conditions for determining alpha, by varying experimental and optical flow settings. The measure of a good alpha was chosen to be that alpha does not vary excessively over a number of video frames. Best conditions of low coefficient of variation of alpha using the Lucas-Kanade optical flow algorithm were found to be when a larger aperture of 15x15 pixels was used, combined with a smaller threshold. Adequate results were found at cell size 40x40 pixels; the improvement in detecting details when smaller cells are used did not reduce the variability of alpha, and required much more computing power. Reduction in variability of alpha can be obtained by spreading the tracked location of a crowd member from a pixel into a rectangle. The Particle Image Velocimetry optical flow algorithm had better correspondence with the velocity vectors of manually tracked crowd members than results obtained using the Lukas-Kanade method. Here, also, it was found that 40x40 pixel cells were better than 15x15. A second attempt at quantifying the correlation between optical flow and actual crowd member velocities was studied using simulations. Two processes were researched, which utilized geometrical correction of the perspective distortion of the crowd videos. One process geometrically corrects the video, and then obtains optical flow data. The other obtains optical flow data from video, and then geometrically corrects the data. The results indicate that the first process worked better. Correlation was calculated between sets of data obtained from the average of twenty frames. This was found to be higher than calculating correlations between the velocities of cells in each pair of frames. An experiment was carried out to predict crowd tracks using optical flow and a calculated parameter, beta, seems to give promising results.