Current Search: linear polarization resistance (x)
View All Items
- Title
- Evaluating Corrosion Control Alternatives for a Reverse Osmosis, Nanofiltration and Anion-Exchange Blended Water Supply.
- Creator
-
Wilder, Rebecca, Duranceau, Steven, Randall, Andrew, Zhang, Husen, University of Central Florida
- Abstract / Description
-
The research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced...
Show moreThe research reported herein describes the study activities performed by University of Central Florida (UCF) on behalf of the Town of Jupiter Water Utilities (Town). The Town recently changed its water treatment operations from a combination of reverse osmosis (RO), lime softening (LS) and anion-exchange (IX) to a combination of RO, IX and nanofiltration (NF). Although this treatment change provided enhanced water to the surrounding community in terms of better contaminant removal and reduced DBP formation potential, integration of the NF process altered finished water quality parameters including pH, alkalinity and hardness. There was concern that these changes could result in secondary impacts related to accelerated corrosion of distribution system components and subsequent regulatory compliance. In addition, replacement of the LS process altered the in-plant blending operations by creating an unstable intermediate blend composed of RO and IX waters. There were concerns that this intermediate blend was affecting the integrity of in-plant hydraulic conveyance components.UCF developed a corrosion monitoring study to assess the potential impacts related to internal corrosion, water quality and regulatory compliance after integrating NF into the existing water supply. The intended purpose was to further highlight the complexities of corrosion, describe a unique approach to corrosion monitoring as well as offer various recommendations for corrosion control in a system that relies on a blended water supply. Research was conducted in three phases to address the in-plant and distribution system corrosion issues separately and identify appropriate corrosion control treatment alternatives. The three test phases included: a baseline conditions assessment to compare corrosion of the intermediate RO-IX blend with the finished water blend (RO-IX-NF); an in-plant corrosion control evaluation; and a distribution system corrosion control evaluation.A test apparatus was constructed and operated at the Town's facilities to monitor corrosion activity of mild steel, copper and lead solder metal components. The test apparatus consisted of looped PVC pipe segments housed with electrochemical probes and metal coupons to monitor corrosion rates of the metallic components. Electrochemical probes containing metal electrodes were used to obtain instantaneous corrosion rates by means of the Linear Polarization Resistance (LPR) technique while the metal coupons were gravimetrically evaluated for weight loss. The electrochemical probes permitted daily monitoring of each metal's corrosion rates while metal coupons were analyzed at the conclusion of testing and used for comparison. Different test waters flowed through the corrosion rack according to each test phase and relative corrosion rates were compared to evaluate corrosion control techniques.Study findings indicated that the intermediate blend was more corrosive, in general, then the final blend; however, research also indicated that the final blend of water was increasing lead and copper concentrations within the distribution system. An orthophosphate corrosion inhibitor was evaluated for in-plant corrosion control. The inhibitor's performance was assessed by comparing mild steel corrosion rates with and without the chemical. In addition, secondary impacts related to introduction of the chemical were evaluated by pre-corroding the metallic components prior to the introduction of the inhibitor. Results indicated that the inhibitor marginally decreased corrosion rates and increased the turbidity of the water supply. Based on these observations, it was concluded that the inhibitor was not a viable solution for in-plant corrosion control. To resolve in-plant corrosion issues, recommendations were made for modification of in-plant blending operations to eliminate the corrosive intermediate blend from the process allowing the RO, IX and NF treated waters to be blended in a common location. The effectiveness of a poly/ortho blended phosphate chemical inhibitor was evaluated for reducing lead and copper corrosion to resolve distribution corrosion issues. A 50/50 poly/ortho blend was selected because of its analogous use in similar municipal water facilities. Metallic corrosion rates, particularly lead and copper, were compared with and without the inhibitor to assess the performance of the chemical. Like the previous test phase, the metallic components were pre-corroded prior to the chemical's introduction to determine if secondary impacts could result from its presence. Results indicated that lead and copper corrosion rates were lower in the presence of the inhibitor, and secondary impacts related to increased turbidity were not observed for this chemical. Based on these results, it was recommended that a poly/ortho blended phosphate be used to decrease lead and copper corrosion within the Town's distribution system.
Show less - Date Issued
- 2012
- Identifier
- CFE0004460, ucf:49349
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004460
- Title
- Control of Metal-Release and Tuberculation in a Silica-Laden Groundwater Distribution System on the Volcanic Island of Lana'i.
- Creator
-
Myers, Samantha, Duranceau, Steven, Sadmani, A H M Anwar, Lee, Woo Hyoung, University of Central Florida
- Abstract / Description
-
A corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several...
Show moreA corrosion control study for two distinct water distribution systems (WDS) has been completed for the Pulama Lana'i Water Company (Pulama). This project evaluated the use of chemical inhibitors to control corrosion and tuberculation within the Manele Bay WDS and the Lana'i City WDS. Pulama provides water to a population of 3,100 residents and is considering incorporating alternative water supplies in the future. Hence, knowing baseline corrosion rates within the WDS was desired.Several groundwater wells feed each of the WDS's; however, water quality between wells varies. Well water supplied to the WDS's is generally of high quality, therefore, the historical treatment method has been limited to disinfection prior to distribution. The distribution system consists of several materials of construction, which includes galvanized iron. Valves and pipes within the WDS were experiencing visible corrosion and tuberculation believed to be responsible for variable pressure drop throughout portions of the system.In this work, two corrosion racks, each consisting of two parallel loops, were designed, constructed, and installed at each site. One loop was maintained as a control while the other loop was used for testing alternative corrosion inhibitors. The racks utilized metal sample coupons and linear polarization resistance probes to provide data on corrosion rates of selected metals of interest.Results indicated that the water in Manele Bay experienced no noticeable change between the test loop and control loop when a corrosion inhibitor was added. A first experiment found the corrosion rates reached baseline steady(-)state at 4,000 operational hours. A second experiment found that the corrosion rates reached baseline steady(-)state at 2,200 operational hours. During these two experiments, the addition of a phosphate or silica(-)based inhibitor neither reduced nor increased the corrosion rates of mild steel, lead, and copper.Results from Lana'i City indicated that inhibitors offered little to no positive effect between the control condition and the test condition. During the first experiment, baseline corrosion was reached after 2,400 hours. The addition of a phosphate inhibitor did not reduce nor increase the corrosion rates of mild steel and lead. However, the corrosion rate of copper increased to 1.0mpy from 0.22mpy. The corrosion rate remained elevated after inhibitor feed was terminated. The second experiment reached baseline corrosion rates at 1,400 operational hours. The use of silica inhibitor neither reduced nor increased the corrosion rate of mil steel, lead, and copper.Since corrosion inhibitors were found to be ineffective, a valve exercise and replacement program for Pulama's assets was recommended. This program included: (1) developing a detailed asset inventory, (2) implementing operation and maintenance tasks, (3) forming a valve replacement plan, and (4) establishing long range financial planning. An opinion of probable replacement cost for 200 new valves was conceptually estimated to approximate 3.3 million dollars expended over a 20 year time frame.
Show less - Date Issued
- 2016
- Identifier
- CFE0006152, ucf:51152
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0006152