Current Search: reversible system (x)
View All Items
- Title
- RESEARCHES ON REVERSE LOOKUP PROBLEM IN DISTRIBUTED FILE SYSTEM.
- Creator
-
Zhang, Junyao, Wang, Jun, University of Central Florida
- Abstract / Description
-
Recent years have witnessed an increasing demand for super data clusters. The super data clusters have reached the petabyte-scale can consist of thousands or tens of thousands storage nodes at a single site. For this architecture, reliability is becoming a great concern. In order to achieve a high reliability, data recovery and node reconstruction is a must. Although extensive research works have investigated how to sustain high performance and high reliability in case of node failures at...
Show moreRecent years have witnessed an increasing demand for super data clusters. The super data clusters have reached the petabyte-scale can consist of thousands or tens of thousands storage nodes at a single site. For this architecture, reliability is becoming a great concern. In order to achieve a high reliability, data recovery and node reconstruction is a must. Although extensive research works have investigated how to sustain high performance and high reliability in case of node failures at large scale, a reverse lookup problem, namely finding the objects list for the failed node remains open. This is especially true for storage systems with high requirement of data integrity and availability, such as scientific research data clusters and etc. Existing solutions are either time consuming or expensive. Meanwhile, replication based block placement can be used to realize fast reverse lookup. However, they are designed for centralized, small-scale storage architectures. In this thesis, we propose a fast and efficient reverse lookup scheme named Group-based Shifted Declustering (G-SD) layout that is able to locate the whole content of the failed node. G-SD extends our previous shifted declustering layout and applies to large-scale file systems. Our mathematical proofs and real-life experiments show that G-SD is a scalable reverse lookup scheme that is up to one order of magnitude faster than existing schemes.
Show less - Date Issued
- 2010
- Identifier
- CFE0003504, ucf:48970
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0003504
- Title
- SOLITARY WAVE FAMILIES IN TWO NON-INTEGRABLE MODELS USING REVERSIBLE SYSTEMS THEORY.
- Creator
-
Leto, Jonathan, Choudhury, S. Roy, University of Central Florida
- Abstract / Description
-
In this thesis, we apply a recently developed technique to comprehensively categorize all possible families of solitary wave solutions in two models of topical interest. The models considered are: a) the Generalized Pochhammer-Chree Equations, which govern the propagation of longitudinal waves in elastic rods, and b) a generalized microstructure PDE. Limited analytic results exist for the occurrence of one family of solitary wave solutions for each of these equations. Since, as mentioned...
Show moreIn this thesis, we apply a recently developed technique to comprehensively categorize all possible families of solitary wave solutions in two models of topical interest. The models considered are: a) the Generalized Pochhammer-Chree Equations, which govern the propagation of longitudinal waves in elastic rods, and b) a generalized microstructure PDE. Limited analytic results exist for the occurrence of one family of solitary wave solutions for each of these equations. Since, as mentioned above, solitary wave solutions often play a central role in the long-time evolution of an initial disturbance, we consider such solutions of both models here (via the normal form approach) within the framework of reversible systems theory. Besides confirming the existence of the known family of solitary waves for each model, we find a continuum of delocalized solitary waves (or homoclinics to small-amplitude periodic orbits). On isolated curves in the relevant parameter region, the delocalized waves reduce to genuine embedded solitons. For the microstructure equation, the new family of solutions occur in regions of parameter space distinct from the known solitary wave solutions and are thus entirely new. Directions for future work, including the dynamics of each family of solitary waves using exponential asymptotics techniques, are also mentioned.
Show less - Date Issued
- 2008
- Identifier
- CFE0002151, ucf:47930
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0002151
- Title
- Smooth and Non-Smooth Traveling Wave Solutions of Some Generalized Camassa-Holm Equations.
- Creator
-
Rehman, Taslima, Choudhury, Sudipto, Nevai, Andrew, Rollins, David, University of Central Florida
- Abstract / Description
-
In this thesis we employ two recent analytical approaches to investigate the possible classes of traveling wave solutions of some members of recently derived integrable family of generalized Camassa-Holm (GCH) equations. In the first part, a novel application of phase-plane analysis is employed to analyze the singular traveling wave equations of four GCH equations, i.e. the possible non-smooth peakon, cuspon and compacton solutions. Two of the GCH equations do no support singular traveling...
Show moreIn this thesis we employ two recent analytical approaches to investigate the possible classes of traveling wave solutions of some members of recently derived integrable family of generalized Camassa-Holm (GCH) equations. In the first part, a novel application of phase-plane analysis is employed to analyze the singular traveling wave equations of four GCH equations, i.e. the possible non-smooth peakon, cuspon and compacton solutions. Two of the GCH equations do no support singular traveling waves. We generalize an existing theorem to establish the existence of peakon solutions of the third GCH equation. This equation is found to also support four segmented, non-smooth M-wave solutions. While the fourth supports both solitary (peakon) and periodic (cuspon) cusp waves in different parameter regimes.In the second part of the thesis, smooth traveling waves of the four GCH equations are considered. Here, we use a recent technique to derive convergent multi-infinite series solutions for the homoclinic and heteroclinic orbits of their traveling-wave equations, corresponding to pulse and front (kink or shock) solutions respectively of the original PDEs. Unlike the majority of unaccelerated convergent series, high accuracy is attained with relatively few terms. Of course, the convergence rate is not comparable to typical asymptotic series. However, asymptotic solutions for global behavior along a full homoclinic/heteroclinic orbit are currently not available.
Show less - Date Issued
- 2013
- Identifier
- CFE0004918, ucf:49637
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0004918
- Title
- In-Plant and Distribution System Corrosion Control for Reverse Osmosis, Nanofiltration, and Anion Exchange Process Blends.
- Creator
-
Jeffery, Samantha, Duranceau, Steven, Randall, Andrew, Wang, Dingbao, University of Central Florida
- Abstract / Description
-
The integration of advanced technologies into existing water treatment facilities (WTFs) can improve and enhance water quality; however, these same modifications or improvements may adversely affect finished water provided to the consumer by public water systems (PWSs) that embrace these advanced technologies. Process modification or improvements may unintentionally impact compliance with the provisions of the United States Environmental Protection Agency's (USEPA's) Safe Drinking Water Act ...
Show moreThe integration of advanced technologies into existing water treatment facilities (WTFs) can improve and enhance water quality; however, these same modifications or improvements may adversely affect finished water provided to the consumer by public water systems (PWSs) that embrace these advanced technologies. Process modification or improvements may unintentionally impact compliance with the provisions of the United States Environmental Protection Agency's (USEPA's) Safe Drinking Water Act (SDWA). This is especially true with respect to corrosion control, since minor changes in water quality can affect metal release. Changes in metal release can have a direct impact on a water purveyor's compliance with the SDWA's Lead and Copper Rule (LCR). In 2010, the Town of Jupiter (Town) decommissioned its ageing lime softening (LS) plant and integrated a nanofiltration (NF) plant into their WTF. The removal of the LS process subsequently decreased the pH in the existing reverse osmosis (RO) clearwell, leaving only RO permeate and anion exchange (AX) effluent to blend. The Town believed that the RO-AX blend was corrosive in nature and that blending with NF permeate would alleviate their concern. Consequently, a portion of the NF permeate stream was to be split between the existing RO-AX clearwell and a newly constructed NF primary clearwell. The Town requested that the University of Central Florida (UCF) conduct research evaluating how to mitigate negative impacts that may result from changing water quality, should the Town place its AX into ready-reserve. The research presented in this document was focused on the evaluation of corrosion control alternatives for the Town, and was segmented into two major components: 1.The first component of the research studied internal corrosion within the existing RO clearwell and appurtenances of the Town's WTF, should the Town place the AX process on standby. Research related to WTF in-plant corrosion control focused on blending NF and RO permeate, forming a new intermediate blend, and pH-adjusting the resulting mixture to reduce corrosion in the RO clearwell. 2.The second component was implemented with respect to the Town's potable water distribution system. The distribution system corrosion control research evaluated various phosphate-based corrosion inhibitors to determine their effectiveness in reducing mild steel, lead and copper release in order to maintain the Town's continual compliance with the LCR.The primary objective of the in-plant corrosion control research was to determine the appropriate ratio of RO to NF permeate and the pH necessary to reduce corrosion in the RO clearwell. In this research, the Langelier saturation index (LSI) was the corrosion index used to evaluate the stability of RO:NF blends. Results indicated that a pH-adjusted blend consisting of 70% RO and 30% NF permeate at 8.8-8.9 pH units would produce an LSI of +0.1, theoretically protecting the RO clearwell from corrosion.The primary objective of the distribution system corrosion control component of the research was to identify a corrosion control inhibitor that would further reduce lead and copper metal release observed in the Town's distribution system to below their respective action limits (ALs) as defined in the LCR. Six alternative inhibitors composed of various orthophosphate and polyphosphate (ortho:poly) ratios were evaluated sequentially using a corrosion control test apparatus. The apparatus was designed to house mild steel, lead and copper coupons used for weight loss analysis, as well as mild steel, lead solder and copper electrodes used for linear polarization analysis. One side of the apparatus, referred to as the (")control condition,(") was fed potable water that did not contain the corrosion inhibitor, while the other side of the corrosion apparatus, termed the (")test condition,(") was fed potable water that had been dosed with a corrosion inhibitor. Corrosion rate measurements were taken twice per weekday, and water quality was measured twice per week. Inhibitor evaluations were conducted over a span of 55 to 56 days, varying with each inhibitor. Coupons and electrodes were pre-corroded to simulate existing distribution system conditions. Water flow to the apparatus was controlled with an on/off timer to represent variations in the system and homes. Inhibitor comparisons were made based on their effectiveness at reducing lead and copper release after chemical addition. Based on the results obtained from the assessment of corrosion inhibitors for distribution system corrosion control, it appears that Inhibitors 1 and 3 were more successful in reducing lead corrosion rates, and each of these inhibitors reduced copper corrosion rates. Also, it is recommended that consideration be given to use of a redundant single-loop duplicate test apparatus in lieu of a double rack corrosion control test apparatus in experiments where pre-corrosion phases are implemented. This recommendation is offered because statistically, the control versus test double loop may not provide relevance in data analysis. The use of the Wilcoxon signed ranks test comparing the initial pre-corroding phase to the inhibitor effectiveness phase has proven to be a more useful analytical method for corrosion studies.
Show less - Date Issued
- 2013
- Identifier
- CFE0005008, ucf:50001
- Format
- Document (PDF)
- PURL
- http://purl.flvc.org/ucf/fd/CFE0005008